operating your appliance
EN

2.2.1 changing the batteries

WARNING
!
Ensure the gas and electrical power to the appliance is turned off.
Appliance may be hot, do not service until the appliance has cooled.
4 AA batteries must be installed into the receiver before the appliance can
operate by battery backup. The receiver is located in the bottom right corner
of the appliance (Fig. 1).
note:
Ensure the 3 position slider switch is in the "REMOTE" position (middle
position).

Receiver Removal

1. Remove the right access panel from the side of the appliance.
2. Remove the front 2 screws from the inside edge (Fig. 2) and swing the
control door open.
note:
If your opening is too small, you may need to pull the appliance out
slightly.
3. Remove the 2 screws holding the receiver in place.
4. Remove the receiver and replace.
2.3

bracket installation for optional F45/60 receiver (GDI3 only)

1. Remove the safety barrier and glass door (see "safety barrier & door removal / installation" section).
2. Remove the 1 screw holding the bracket in place (Fig. 1). Lift the bracket up and out of the slots, lifting it
through the opening between the fi rebox and the appliance's outer shell (Fig. 2).
3. Insert optional receiver (F45 or F60). Secure the receiver using 2 screws (supplied).
4. Place the bracket and receiver back through the opening between the fi rebox and the appliance's outer shell.
Slide the bracket and receiver into and down the slots (Fig. 2 in reverse).
5. Resecure the 1 screw to hold the bracket and receiver in place (Fig. 1).