Contrôle des réglages - suite
n94
Step/speed
n95
Control type
Alarm/Safety Settings
A03
Saux 1 High alarm del
A10
Po Max alarm °C
A11
Po Min limit °C
A28
Low liquid level delay
A30
Pc Max limit °C
A35
Saux 1 High alarm °C
A44
Po Max delay m
A45
Pc Max alarm delay m
A58
Sd max limit°C
A59
SH min alarm K
A60
SH max alarm K
A61
SH alarm delay
A62
Safety restart time m
A64
VSDcutoutDel
Misceallanous
o12
Mains frequency
o19
No. of compressors
o21
Po sensor
o23
Comp. 1 Runtime
o24
Comp. 2 Runtime
o25
Comp. 3 Runtime
o26
Comp. 4 Runtime
o30
Refrigerant type
o48
Pc sensor
o50
Comp. 5 Runtime
o51
Comp. 6 Runtime
o61
Quick setup select
o93
Configuration lock
AK-PC 710
W
"Select control mode for condenser
0: Step: Fans are step-connected via relay outputs
1: Step/speed: The fan capacity is controlled via a combination of speed
control and step coupling
2: Speed: The fan capacity is controlled via speed control (frequency
converter)"
W
"Choice of control strategy for condenser
0: P-band: The fan capacity is regulated via P-band control. The P band is
configured as ""Proportional band Xp""
1: PI-Control: The fan capacity is regulated by the PI controller"
W
Alarm delay for high Saux temperature
W
Alarm limit for high suction pressure Po
W
"Minimum value for the suction pressure in °C
If the limit is reduced, the entire compressor capacity will be cutout."
W
Time delay for the low liquid level alarm
W
"Maximum value for the condenser pressure in °C
3 K below the limit, the entire condenser capacity will be cutin and the
compressor capacity reduced.
If the limit is exceeded, the entire compressor capacity will be cutout."
W
High temp. alarm limit for Saux sensor
W
Time delay before alarm for high suction pressure P0.
W
Time delay for the alarm Pc max
W
"Max. value for discharge gas temperature
10 K below the limit, the compressor capacity should be reduced and the
entire condenser capacity will be cutin.
If the limit is exceeded, the entire compressor capacity will be cutout"
W
Alarm limit for min. superheat in suction line.
W
Alarm limit for max. superheat in suction line.
W
Time delay before alarm for min./max. superheat in suction line.
W
"Common time delay before restarting the compressor.
(Applicable to the functions: ""Sd max. limit"", Pc max. limit"" and ""P0 min.
limit)."
W
Time delay before VSD alarm
W
Select frequency of the power supply
R
Readout number of compressors
W
Select sensor type for Po
0: User defined, 1=AKS32-6, 2=AKS32R-6, 4=AKS32-9, 5=AKS32R-9,
7=AKS32-12, 8=AKS32R-12, 10=AKS32-20, 11=AKS32R-20, 13=AKS32-34,
14=AKS32R-34, 16=AKS32-50, 17=AKS32R-50, 31=AKS2050-59,
32=AKS2050-99, 33=AKS 2050-159
W
Compressor's total run time in hours
W
Compressor's total run time in hours
W
Compressor's total run time in hours
W
Compressor's total run time in hours
W
Select refrigerant type for Po
1=R12, 2=R22, 3=134a, 4=R502, 5=R717, 6=R13, 7=R13b1, 8=R23,
9=R500, 10=R503, 11=R114, 12=R142b, 13=User def., 14=R32, 15=R227,
16=R401A, 17=R507, 18=R402A, 19=R404A, 20=R407C, 21=R407A,
22=R407B, 23=R410A, 24=R170, 25=R290, 26=R600, 27=R600a, 28=R744,
29=R1270, 30=R417A. 31=R422A, 32=R413A, 33=R422D, 34=R427A,
35=R438A, 36=XP10, 37=R407F
W
Select sensor type for Po
0: User defined, 1=AKS32-6, 2=AKS32R-6, 4=AKS32-9, 5=AKS32R-9,
7=AKS32-12, 8=AKS32R-12, 10=AKS32-20, 11=AKS32R-20, 13=AKS32-34,
14=AKS32R-34, 16=AKS32-50, 17=AKS32R-50, 31=AKS2050-59,
32=AKS2050-99, 33=AKS 2050-159
W
Compressor's total run time in hours
W
Compressor's total run time in hours
W
"Select a predefined application.
Gives a choice between a number of predefi¬ned applicatons, which at the
same time determine the wiring connection points.
(see manual for further details)"
W
The controller can only be configured when it is unlocked.
Régulation de capacité RS8FT404 © Danfoss 03-2013
0: Step control
0: Step
1: Step/Speed
2: Speed
0: P-band control
1: PI control
1: PI control
0 - 360 min
5 min
-30,0 °C - 100,0 °C
100,0 °C
-120,0 °C - 30,0 °C
-40,0 °C
0 - 360 min
5 min
-30,0 °C - 100,0 °C
50,0 °C
-80,0 °C - 120,0 °C
120,0 °C
0 - 240 min
5 min
0 - 240 min
0 min
-0,0 °C - 150,0 °C
80,0 °C
0,0 - 20,0 K
0,0 K
20,0 - 80,0 K
80,0 K
0 - 60 min
5 min
0 - 60 min
5 min
0-360 min
5 min
0: 50 Hz
0: 50 Hz
1: 60 Hz
0 - 6
0
0-33
8
0 - 999999 h
0 h
0 - 999999 h
0 h
0 - 999999 h
0 h
0 - 999999 h
0 h
0: None
37
0-33
14
0 - 999999 h
0 h
0 - 999999 h
0 h
See documenation
0: None
for quick selections
selected
0: Unlocked
0: Unlocked
1: Locked