Product Description; General Information; Technical Data; Maximum Load - Daikin AHT CB 124 Traduction De La Notice Originale

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 49

3 | Product description

3
Product description
3.1

General information

AHT products comply with EU Regulation 1907/2006
(REACH) on the Registration, Evaluation, Authorisa-
tion and Restriction of Chemicals.
3.2

Technical data

Important technical data can be found on the power
rating plate [see } Chapter 3.2.1].
Parameter
Value
See →Appliance model over-
External dimensions
view
See →Appliance model over-
Appliance weight
view
Refrigerant
Propane (R-290)
Refrigerant per refri-
≤ 150 g
gerant circuit
Ozone depletion po-
tential (ODP)
0
Propane (R-290)
Insulation gas
PENTAN
Ozone depletion po-
tential (ODP)
0
PENTAN
Global Warming Po-
tential (GWP)
3
Propane (R-290)
Airborne noise emit-
ted/emission sound
< 70 dB(A)
pressure level
CB TWA 124, CB TWA 196
Defrosting water
DN 32
drain

Maximum load

Parameter
Value
Sticker at the top right of the in-
Storage racks
side of the equipment cover
next to the power rating plate
CB 124, CB TWA 124
Display shelf/pieces 60 kg
Bottom shelf/pieces 60 kg
CB 196, CB TWA 196
Display shelf/pieces 42 kg
Bottom shelf/pieces 42 kg
Bus system
Bus system
AHT Inter Cabinet BUS (ICB)
(Communication)
CAT 5-S/FTP (PIN 1 ... 8 as-
Bus cable
signed) RJ45
34 / 220
Electrical connection
Minimum cross-sec-
tion for connecting
1.5 mm²
cables
CB 196, CB TWA 196
rated voltage
3N 380 – 420 V
rated frequency
50 Hz
Plug types
CEE 5 x 16 A
Plug types
National versions
5-pin cable with protective con-
Connecting cable
ductor (PE) and neutral con-
ductor (N)
CB 124, CB TWA 124
rated voltage
220 – 240 V
rated frequency
50 Hz
Plug types
CEE 7/7
Plug types
National versions
Connecting cable
3-pin cable
Control line (night blind/appliance lighting)
rated voltage
220 – 240 V
rated frequency
50 Hz
Plug types
CEE 7/7
Plug types
National versions
Connecting cable
3-pin cable
Fusing
[see } Chapter 8.2]
Rated
Fault
Type
cur-
cur-
rent
rent
[A]
[mA]
Circuit breaker (LS/CB)
16
-
-
Residual current circuit breaker (FI/RCCB/GFCI)
G (short-time delay)
A (pulse current-sensit-
ive)/
40
30
F (mixed frequency-sens-
itive)/
B (universal current-sens-
itive)
Residual current circuit breaker with overcurrent pro-
tection FI-LS/RCBO (alternative to RCCB and CB)
G (short-time delay)
A (pulse current-sensit-
ive)/
16
30
F (mixed frequency-sens-
itive)/
B (universal current-sens-
itive)
Custom deviations possible.
More information: Maintenance services
[see } Chapter 11.2.5]
AHT Cooling Systems GmbH | en
Tripping
charac-
teristic
C (slow-
acting)
-
C (slow-
acting)
440031_1_0321

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Aht cb 196

Table des Matières