OPERATING IRREGULARITIES

PROBLEM
Motor does not work
Motor works but there is nofla-
me formation and with
The burner starts. There is the
formation of the flame and then
stops in block
Flame is irregular and small
Flame is smokey
PROBABLE CAUSE
No power supply
a) electrodes are not discharged
b) nozzle is dented
a) photoresistance is dirty
a) nozzle is pulverizing badly
b) pump pressure is too low
a) nozzle is pulverizing badly
SOLUTION
a) check fuses
b) check thermostats
a) check correct position of tip-
sand clean them
b) clean or replace nozzle
c) check Light Oil level in tank
and that there are no shutters
closed along the Light Oil line.
a) clean the photoresistance
a) clean or replace nozzle
b) check and increase pressure
c) extract water from tank and
clean the filter
a) clean or replace nozzle
b) check atmospheric air flap
opens normally. Check that fan
UK