Electromagnetic Interferences And Electromagnetic Compatibility Tables - I-Tech MIO-PERISTIM Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

In order to preserve the warranty, the functionality and the security and
safety of the product, it is highly recommended to use exclusively the spare
parts given by the manufacturer.
Electromagnetic
compatibility tables
The MIO-PERISTIM equipment has been designed and manufactured
according
to
COMPATIBILITY legislation EN 60601-1-2:2015 with the aim of providing
adequate protection from harmful interference when installed in homes and
health establishments.
The equipment does not generate significant radio frequency energy and is
adequately immune to radiated electromagnetic fields. Therefore, it does not
detrimentally interfere with radio-electric communications, electro-medical
equipment for monitoring, diagnosis, therapy and surgery, office electronic
devices such as computers, printers, photocopiers, fax machines, etc. or any
electric or electronic equipment used in these environments, as long as the
equipment complies with the ELECTROMAGNETIC COMPATIBILITY directive.
In general, the use of accessories other than those specified or provided by
the manufacturer could result in increased electromagnetic emissions or
decreased electromagnetic immunity of the MIO-PERISTIM and result in
improper functioning.
In any case, in order to avoid any interference problems, it is recommended
to use the therapy equipment enough far away from critical equipment for
monitoring vital patient functions, and to be careful when applying therapy to
patients with pacemakers. In any case it is recommended to use the
equipment at least at 3 meters away from televisions, monitors, cellphones or
any other electronic equipment, in particular portable RF communications
equipment (including peripherals such as antenna cables and external
antennas) should not be used closer than 30cm (12 inches) to any part of the
device, including the cables specified by the manufacturer; otherwise, it could
lead to degradation of the performance of the MIO-PERISTIM.
In conclusion, the use of MIO-PERISTIM adjacent to or stacked with other
equipment should be avoided, since it could cause improper functioning. If
such use is necessary, the MIO-PERISTIM and the other equipment should be
constantly observed to verify that they are operating normally.
When MIO-PERISTIM is used in an environment relatively dry, strong
electromagnetic interferences usually occur. At this time, the device may be
affected as follows:
IACER Srl
interferences
the
TECHNICAL
and
STANDARD
on
74
electromagnetic
ELECTROMAGNETIC
MNPG152-07

Publicité

Table des Matières
loading

Table des Matières