TROUBLE SHOOTING
PROBLEM
Machine not operating.
Brush not turning.
Poor pick--up.
Vacuum motor not
operating.
SPECIFICATIONS
MODEL
LENGTH
WIDTH
HEIGHT
WEIGHT
CLEANING PATH WIDTH
COVERAGE RATE (MAX)
VACUUM BAG
BRUSH MOTOR
VACUUM MOTOR
WATERLIFT AT SEALED ORIFICE
DECIBEL RATING AT OPERATOR'S EAR, INDOORS ON
CARPET
POWER CORD LENGTH
V- -WA- -30 (04- -10)
CAUSE
Power cord not plugged in.
Damaged power cord.
Tripped circuit breaker in building.
Loose or damaged internal wiring.
Machine circuit bnreaker tripped.
Broken belt.
Belt not adjusted properly.
Defective brush switch.
Defective brush motor.
Filter bag full.
Secondary vacuum filters dirty.
Air flow lever in wrong position.
Brush intake area obstructed.
Pick--up hose or housing plugged.
Gasket leak.
Brush not adjusted properly.
Worn brush.
Thermal overloads activated due to plug or
obstruction.
Vacuum switch defective.
Find... Go To..
SOLUTION
Connect to power supply.
Contact Service Center.
Reset breaker in building.
Contact Service Center.
Reset breaker. Check for brush obstruc-
tion or low brush setting.
Replace belt.
Readjust belt.
Contact Service Center.
Contact Service Center.
Empty bag.
Clean and replace.
Move lever to proper setting.
Check for obstruction and remove.
Check for obstruction and remove.
Replace gasket.
Reset brush adjustment.
Adjust or replace.
Inspect and clean.
Contact Service Center.
V- -WA- -30
39.75 in / 1010 mm
30.5 in / 775 mm
36 in / 914 mm
91 lb / 41.28 Kg
30 in / 762 mm
2
14,000 sq ft / 4,267 m
per hour
1 bushel / 35.24 L
.25hp, 1200 rpm, 120V, .75A, 90W
Two 1 hp, 1--stage 5.7 in, 120V, 11A, 1320W
48 in / 1219 mm
74dBA
75 ft / 23 m
OPERATION
EN
9