PREPARE THE WALL
1. Disconnect and move freestanding range from cabinet
opening to provide easier access to upper cabinet and rear
wall. Put a thick, protective covering over cooktop, set-in
range or countertop to protect from damage or dirt.
2. It is recommended that the vent system be installed
before hood is installed. Before making cutouts, make sure
there is proper clearance within the ceiling or wall for exhaust
vent. Check that all installation parts have been removed
from the shipping carton. First, disconnect power.
Then determine which venting method to use: roof, wall
or rear exhaust.
CHANGING HOOD TO OPTIONAL REAR EXHAUST
The hood comes from the factory with the exhaust
collar on top of the hood. The hood exhaust may be directed out the rear of
the hood through the exhaust collar. If you desire to have the hood exhaust
out the rear, follow the procedure below.
1. From inside the hood, unplug wire attached to blower motor.
A. Blower Motor
B. Blower motor plug
2. Turn the hood over and remove the screws holding the exhaust blower
assembly to the hood.
A. Blower Motor
B. Screws
3. Rotate the blower assembly so that the exhaust collar is
facing out the back of the hood.
4. Replace the screws holding the blower assembly
to the hood.
5. Plug the blower motor wire back into the blower
motor.
RANGE HOOD MOUNTING SCREWS INSTALLATION
The hood attaches to the wall with two mounting brackets
with adjustment screws and four mounting screws.
1. Determine and mark the centerline on the wall where
the canopy range hood will be installed.
2. Select a mounting height between a minimum of 30"
and a suggested maximum of 36", above the
cooking surface and the bottom of the range hood. To this
distance, add 16" and mark a horizontal line.
3. Mark 2 points on each side of the horizontal line the
distance shown in "A" below (based on the size of your
range hood).
A: Distance from center of mounting bracket to centerline:
30" hood: 13 3/8" / 36" hood: 16 3/8" /
42" hood: 19 7/16" / 48" hood: 22 3/8"
B: Mounting Screws (4)
C: Mounting brackets and adjustment screws
D: Bottom of hood
4. Adjust the two adjusting screws on the mounting brackets
to the lowest point and attach to the wall with the screws
provided. The screws provided for mounting this hood must
be fastened into solid wood. Do not fasten into sheet rock
only.
A. Exhaust blower assembly
B. Screws
C. Exhaust collar
Version 09/12- Page 6