Simpool Timer Model
Programmable digital peristaltic pump
n.d.1-d.8: it allows you to display or set the corresponding dosage starting minutes d.1- d.8 using the ▲
and ▼ keys (range 0-59');
t.d.1-d.8: it allows you to display or set the corresponding dosage length d.1- d.8 expressed in minutes
using the ▲ and ▼ keys (range 0-60');
To go back to the main do.C entry of the Programming Menu, press Enter for 3 seconds.

3.3.3 Displaying and Resetting Statistics

From the StA entry on the Programming Menu you can access the Pump statistics submenu (see Fig. 10).
Here below is the parameter saved during the pump operation:
The pump's overall operating time P.d.t, from 0 to 999 hours, with the following format:
- h.mm up to 9 h and 59 m
- hh.m up to 99 h and 59 m (minutes expressed in tens)
- hhh up to 999 h
To reset each of the above-mentioned fields, just access from the numerical value the rSt reset entry with the F
key and from there select YES, confirming with Enter. You will go back to the t.F.P. entry.
To go back to the Programming Menu press Enter for 3 seconds.
ADSP7000722
Fig. 9- Dosage time and length setting - Programming
Fig. 10 - Statistics Menu
rev. 1.0