Simpool Timer Model
Programmable digital peristaltic pump
▪ Enable the bu.E buzzer when an alarm is activated: to enter and exit the submenu, use the Enter key, use
the ▲ and ▼ keys to choose "YES/no";
To go back to the Programming Menu, to the Opt entry, just press Enter for 3 seconds from any entry of the Menu.

4.0 ALARMS

The entry that reports the active alarm with the top priority is only displayed alternated with the entries of the Initial
Menu, while there will be an audio signal (if the buzzer is enabled) and a flashing red LED associated with the
status of the Alarm both on the Initial Menu and the User Menu.

4.1 MAINTENANCE ALARM

The maintenance alarm is activated when the pump has been running for longer than the time set in the relative
O.F.d submenu (see
Settings Menu).
If you set 0.00 (h.mm) as a time value for the maintenance alarm, it will be disabled.
This is reported by the pump as follows:
Audio signal via the buzzer (if there is one on the pump) if enabled (see bu.E in the
frequency of 1 second on and 1 second off;
flashing red LED;
"OFd" flashing on the display;
In this alarm status the motor is stationary. To disable the alarm, you need to go to the P.d.t entry (pump operating
time) in the Statistics Menu and reset the value.

4.2 LEVEL ALARM (only for the model with the level probe)

A level probe can be connected to the pump to report the end of the product, which is indicated by the pump in the
following way:
Audio signal via the buzzer (if there is one on the pump) if enabled (see bu.E in the
frequency of 1 second on and 1 second off;
flashing red LED;
"uLo" flashing on the display;
The inlet has a 3-second recognition filter to identify false contacts and unwanted level alarm signals.
This alarm may or may not imply the pump stop, depending on the option chosen in the "P.St" submenu
Menu: P.St=YES→ the pump is stopped; P.St =no → the pump keeps on dosing).
The alarm is automatically reset when the level of the chemical product to be dosed is restored.
In priming mode, the level alarm is not indicated.

4.3 OFF STATUS ALARM

If the switch is left on the OFF position, after 20 minutes the switch alarm is activated and signalled by the pump in
the following way:
Audio signal via the buzzer (if there is one on the pump) if enabled (see bu.E in the
frequency of 1 second on and 1 second off;
flashing red LED;
"OFF" flashing on the display;
Just set the switch to ON to disable it.
ADSP7000722
Fig. 13 - Settings Menu
rev. 1.0