dGdoser Model
Programmable digital peristaltic pump
To go back to the main Con entry of the Programming Menu, press Enter for 3 seconds.
The applied pressure for 3 seconds to set the Set-point, from the reading entry, assumes that the g/l of optimal
detergent has been dissolved in the tank to carry out the wash.
Fig. 13 - Set-point and measured reading value setting from the Programming Menu
3.3.3 D
R
ISPLAYING AND
From the StA entry on the Programming Menu you can access the Pump statistics submenu.
Here below are the parameters saved during the pump's operation:
The pump's overall operating time t.F.P, from 0 to 999 hours, with the following format:
- h.mm up to 9 h and 59 m
- hh.m up to 99 h and 59 m (minutes expressed in tens)
- hhh up to 999 h
Number of times the OFA 1 over-dosage alarm has been activated, indicated by OF1 (from 0 to 999);
Number of times the OFA 2 over-dosage alarm has been activated, indicated by OF2 (from 0 to 999);
To reset each of the above-mentioned fields, just access from the numerical value to the rSt reset entry with the F
key and from there select YES, confirming with Enter: the corresponding reset value is displayed.
ADSP7000634
S
ESETTING
TATISTICS
Fig. 14- Statistics Menu
rev. 1.2
INSTRUCTION AND MAINTENANCE MANUAL
30/06/2014
ENGLISH
49/206