When replacing the HEPA AirClean
50 filter with an AirClean filter, please
note (dia. 32):
If you wish to replace the HEPA AirCle-
an 50 exhaust filter with an AirClean ex-
haust filter, then it is essential that you
also fit the filter grille (see "Optional ac-
cessories").
Maintenance indicator with reset
button (dia. 33)
The indicator lights up after approx. 50
hours of operation, which is equivalent
to about a year of average use. The
level of soiling of the dust compartment
filter and the exhaust filter must be
checked at this point.
If the filters are replaced, the indicator
must be reset. To do this the vacuum
cleaner must be switched on.
^ Press the reset button.
The maintenance indicator will go out
and reset to zero.
The indicator can only be reset by
pressing the reset button after the
light has come on. Pressing the
button at any other time will have no
effect.
Inserting batteries into the LED
handle (dia. 8 + 9)
You will need three 1.5 V (AAA)
batteries.
a Loosen the screws on the cover.
b Press down on both sides of the
cover to remove.
42
c Take out the battery holder and
change the three batteries, making
sure the polarity is correct.
d Replace the battery holder. Make
sure the arrows on the holder and in
the battery compartment line up in
the same direction.
e Replace the cover and tighten the
screws.

When to change the thread lifters

The thread lifters on the suction inlet to
the floorhead can be replaced.
Check them from time to time and
replace them if the pile has worn down.
How to replace the thread lifters (dia.
34)
^ Use a suitable screwdriver to remove
the thread lifters from the slots.
^ Fit new thread lifters.
Replacement parts are available from
your Miele Dealer or from Miele (see
end of booklet for contact details).

Cleaning and care

,
Always disconnect the vacuum
cleaner from the electrical supply
before cleaning it. Switch off at the
wall socket and unplug it.
Vacuum cleaner and accessories
The vacuum cleaner and all plastic
accessories can be cleaned with a dry
or a slightly damp cloth, or with a
proprietary cleaner suitable for plastic.