Maintenance Indicator With Reset Button; When To Replace The Battery In The Radio-Control Handle; How To Change The Battery In The Radio-Control Handle - Miele Complete C3 SG Série Mode D'emploi

Masquer les pouces Voir aussi pour Complete C3 SG Série:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

en
If you are using exhaust filter c, d or
e, you must also activate the
timestrip® filter change indicator
(dia. 11).
2. If you wish to replace exhaust filter b,
c, d or e with filter a it is essential
that you also fit the filter grille* (dia.
42).
* Filter grille – see "Optional ac-
cessories"
Maintenance indicator with reset but-
ton (dia. 45)
Some models are fitted with a mainten-
ance indicator.
The indicator lights up after approx. 50
hours of operation, which is equivalent
to about a year of average use. The
level of soiling of the dust compartment
filter and the exhaust filter must be
checked at this point.
If the filters are replaced, the indicator
must be reset. To do this the vacuum
cleaner must be switched on.
 Press the reset button.
The maintenance indicator will go out
and reset to zero.
The indicator can only be reset by
pressing the reset button after the
light has come on. Pressing the but-
ton at any other time will have no ef-
fect.
When to replace the battery in the ra-
dio-control handle
Change the battery approximately every
18 months. One 3 V battery (CR 2032)
is required.
58
The vacuum cleaner can still be used
when the battery has run out or if
there is no battery fitted.
 Switch the vacuum cleaner on using
the On/Off footswitch .
The standby indicator  on the vacuum
cleaner will light up yellow.
 Press the restart button on the va-
cuum cleaner.
The vacuum cleaner can continue to be
used, but only at maximum power.
Keep batteries out of the reach
of children.
A swallowed battery can cause injury
and even death. Even flat batteries
can still be dangerous. If you suspect
a child has swallowed a battery, seek
medical advice immediately*. Exam-
ine devices and make sure the bat-
tery compartment is correctly se-
cured, e.g. that the screw or other
mechanical fastener is tightened. Do
not use if compartment is not secure.
* Australia: Poisons Information
Centre, Tel. 13 11 26;
NZ: National Poisons Centre,
Tel. 0800 764 766
How to change the battery in the ra-
dio-control handle (dia. 46)
 Undo the screw on the battery com-
partment cover using a cross-tip
screwdriver and then remove the
cover.
 Replace the battery with a new one.
Make sure the polarity is correct.
 Replace the cover and tighten the
screw back up again.

Hide quick links:

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Hs15

Table des Matières