Continuity; Resistance (C.a 6523 And C.a 6525) - Chauvin Arnoux C.A 6521 Notice De Fonctionnement

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
Analogue calibre
Resolution
8 segments per
Accuracy
5 % L ± 1 segment
Digital
0.01 to
0.20 to
calibres
0.19 MΩ
39.99 MΩ 399.9 MΩ
Resolution
10 kΩ
Accuracy
3% R ± 5 ct
Test voltage
250 V
Voltage at
< 300 V
open circuit
≥ 1 mA
Test current
for R ≤ 250 kΩ
Short-circuit
current
Once the yellow key has been released, the residual voltage
present on the terminals is discharged via the measuring cords
through the apparatus at the speed of 1.5 s/μF and in an
impedance of 300 Ω.
■ Average charging time depending on the capacity in
parallel on the resistance to be measured.
500 V
3 s
1 MΩ
3 s
6 s
100 MΩ
20 s

6.2.3. Continuity

Measurement range : 0 to 20 Ω
Calibre
0.00...19.90 Ω
Resolution
10 mΩ
Accuracy
± 3% L ± 1 pt
Measuring current
≥ 200 mA
Voltage at open circuit
7 V ≤ V

6.2.4. Resistance (C.A 6523 and C.A 6525)

Measurement range : 0 to 400 kΩ
Calibres
0.0...399.9 Ω 400..3999 Ω 4.00..39.99 kΩ 40.0..399.9 kΩ
auto.
Resolution
0.1 Ω
Accuracy
± 3% L ± 5 pt
Test
55 or 550 μA according to the measurement
current
Voltage at
7 V ≤ V open ≤ 9 V
open circuit
50 kΩ...2 GΩ
10-unit interval
40.0 to
400 MΩ
to 2 GΩ
100 kΩ
1 MΩ
3% R ± 2 ct
500 V
1000 V
< 600 V
< 1200 V
≥ 1 mA
≥ 1 mA
for R ≤ 500 kΩ
for R ≤ 1 MΩ
≤ 3 mA
1000 V
3 s
1 μF
6 s
5 μF
6 s
1 μF
20 s
5 μF
≤ 9 V
open
1 Ω
10 Ω
100 Ω
± 3% L ± 1 pt
37

Hide quick links:

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

C.a 6523C.a 6525

Table des Matières