Maintenance instructions
&
Clean the device and the ventilation slots with a dry, lint-free cloth.
Procedures in the event of faults
The device is maintenance-free. However, if any faults do occur, please pro-
ceed according to the following table:
Fault
Action
The battery is not
Check all connections from the charger to the battery.
being charged or a
Pay attention to the correct polarity. Unplug the female
fault indicator of
device plugs on the device and unclamp the batteries.
the charge control
The device should be disconnected from all power
panel is blinking.
sources. Clamp the batteries on again and then plug in
the female device plugs. Check the fuses and the mains
connection.
The voltage of the
Start the motor and let it run for approx. 30 seconds.
battery has
Battery voltage rises above 1.5 volt. The charging proc-
dropped below
ess starts automatically.
1.5 volt.
The battery II is
The starter battery does not reach 13.7 Volt.
not charged during
driving operation.
The maximum
The device overheats. Ensure better ventilation of the
charging current is
device.
not reached.
None of the faults
Please contact the manufacturer:
described here
Trautmann GmbH & Co. KG, CALIRA-Apparatebau
seems to apply.
Lerchenfeldstr. 9
But the device still
D-87600 Kaufbeuren
does not work.
Internet: www.calira.de
Service E-Mail: service@calira.de