4. Operation
Configuring the
Slaves
Configuring the
Master
Length Setting
Page 22 of 94
Configure the slaves for Slave mode before configuring the master.
To configure a slave, do the following:
1. Make sure the product is connected to a power source.
2. Press <MENU> repeatedly until MS shows on the display.
3. Press <ENTER>. Yes or No shows on the display.
4. Use <UP> or <DOWN> to select Yes.
5. Press <ENTER>. MS Master shows on the display.
6. Use <UP> or <DOWN> until No shows on the display.
7. Press <ENTER>. MS Mode shows on the display.
8. Use <UP> or <DOWN> until the desired Master/Slave mode (1–3) shows on the display.
9. Press <ENTER>. MS Address shows on the display.
10. Use <UP> or <DOWN> until the desired MS address (1–3) shows.
11. Press <ENTER>. MS and Yes show on the display.
12. Press <MENU>. Yes stops showing on the display.
Configure the master after all the slaves are configured and connected to it.
To configure the master, do the following:
1. Make sure the product is connected to a power source.
2. Press <MENU> repeatedly until MS shows on the display.
3. Press <ENTER>. Yes shows on the display.
4. Press <ENTER>. MS Master shows on the display.
5. Use <UP> or <DOWN> until Yes shows on the display.
6. Press <ENTER>. MS Mode shows on the display.
7. Use <UP> or <DOWN> until the desired Master/Slave mode (1–3) shows.
8. Press <ENTER>. MS Address shows on the display.
9. Press <UP> or <DOWN> until the desired MS address (1–3) shows.
10. Press <ENTER>. MS and Yes show on the display.
11. Press <MENU>. Yes stops showing on the display.
Once the master is configured, select Automatic or Sound mode. For more information see
Automatic Mode
or
Sound
When MS shows on the display, the MotionOrb menu is at the Main programming level,
and pressing <MENU> scrolls through the main level functions.
The MotionOrb comes standard in a 2 meter length but MotionOrb EXTs can be added to make
the MotionOrb up to 4 meters long. Each extension is 1 meter long. The Length setting
configures the MotionOrb for the number of strings attached.
To configure the MotionOrb length, do the following:
1. Press <MENU> repeatedly until Length shows on the display.
2. Press <ENTER>. A length option shows on the display.
3. Press <UP> or <DOWN> until the desired length shows on the display.
4. Press <ENTER>.
5. Press <MENU>. The desired length stops showing on the display.
The MotionOrb functions correctly only if the Length setting matches the total length of
orb strings installed. For example, if the MotionOrb is set to 4M, but the length is only 2
meters long, the effects macros will not display properly and the pixel mapping will not
work.
Mode.