For Ul/Csa Standard Reference Only; Important Safety Instructions; Marking Label - Videotec MAXIMUS MLX Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 57

4.7 For UL/CSA standard reference only.

The flameproof joints are not intended to be repaired.
In the USA, the National Electrical Code (NEC) and in Canada the Canadian Electrical Code (CEC)
apply to electrical equipment used on hazardous industrial premises. These Codes contain
the installation regulations for electrical facilities in all areas and refer to a number of further
standards of other institutions with specifications for the construction and installation of
suitable equipment.

Important safety instructions

WARNING: A SEAL SHALL BE INSTALLED WITHIN 50 mm OF THE ENCLOSURE.
AVERTISSEMENT: UN SCELLEMENT DOIT ÊTRE INSTALLÉ À MOINS DE 50 mm DU BOÎTIER.
WARNING: DO NOT OPEN WHEN EXPLOSIVE ATMOSPHERE IS PRESENT.
AVERTISSEMENT - NE PAS OUVRIR EN PRÉSENCE D'UNE ATMOSPHÈRE EXPLOSIVE
WARNING: POTENTIAL ELECTROSTATIC CHARGING HAZARD – SEE INSTRUCTIONS.
AVERTISSEMENT - DANGER POTENTIEL DE CHARGES ÉLECTROSTATIQUES - VOIR INSTRUCTIONS
CABLE ENTRY AND BRANCHING POINT TEMPERATURE
LA TEMPÉRATURE DE L'ENTRÉE DE CÂBLE ET DU POINT DE BRANCHEMENT
Ambient/Ambiant
+45°C
+55°C
+70°C
Use suitable cable and cable glands.
Utilisez le câble et les presse-étoupes appropriés.
NEMA Types: TYPE 4X, TYPE 6P

Marking label

Fig. 3
MNVCMLX_2222_EN
Cable/Câble
+78.5°C
+88.5°C
+103.5°C
11

Publicité

Table des Matières
loading

Table des Matières