Installation Instructions

Installation Considerations

Clearances and requirements
The chimney hood requires the ducting to be vented to
the exterior of the building. It cannot be used in
conjunction with a recirculation unit.
Hood installation height above a cooktop, rangetop or
range can vary. To obtain the necessary installation height
above a cooktop, rangetop or range, consult the
appliance's installation manual.
inches (mm)
7
7
7/
7/
"
"
16
16
(189)
(189)
18"
(457)
* 30" (762) –
40" (1,016)
*Follow cooking appliance manufacturer's recommendations.
NOTICE: The hood could incur some damage from heat if
a Thermador Professional
operated with multiple burners at high settings under a
hood that is installed at minimum clearances while the
hood is turned off.
Page. 7
Electrical
Zone
®
series range or rangetop is
Hood Width
The hood width should be no less than the width of the
cooking surface. For proper performance, the housing
must cover the entire cooking surface.
For proper performance, the hood must be centered
horizontally above the cooking surface. Where space is
not restricted, a wider hood can be used to increase
capture area.
Distance From Cooking Surface
The installation height ranges from a minimum height of
30'' (762 mm) to a suggested maximum height of 40''
(1,016 mm); however, it is necessary to follow the cooking
appliance manufacturer's installation instructions for
proper hood height.
Unit Weight
This vent hood is heavy. Adequate structure and support
must be provided in all types of installations. When
calculating the load for the housing support system, be
sure to consider the weight of the ventilation unit.
Description
HPCN36WS
HPCN48WS
Integral Blower Model VTN1090R
Integral Blower Model VTN630W
NOTICE:
Installer must account for weight of any materials of
construction when calculating the total dead weight load
of installation, including but not limited to: wall, tile,
mortar, plaster, brick, finishes, partitions, and other
similarly incorporated architectural and structural items.
It is the responsibility of the owner and the installer to
determine if additional requirements and/or standards
apply to specific installations.
Weight
57 lbs (26 kg)
73 lbs (33 kg)
23 lbs (11 kg)
11 lbs (5 kg)