Use
until the
icon appears or disappears from the display.
When an open window is detected, the "Open Window" icon flashes.
Now pressing the
key cancels the "Open Window" action until detection
of the next open window. The
For the optimal operation of the function, it is recommended to install the
appliance near a window.
Suggested Area
The appliance's reaction to windows opening and closing depends on
many factors, such as the temperature set on the appliance, external
temperature, the degree of ventilation inside the room, the radiator's
position and the presence of other heating sources.
The "Open Window" function cannot be activated or deactivated in
"Standby" mode.
If the appliance has detected an open window, all the operating modes
and the "Overdrive (2h)" function can be selected, however they will not
be active until the window is detected as closed or the "Open Window"
function is cancelled. The "Children Safety" and "Keypad Lock" functions
remain active and can be activated and deactivated even when the
appliance has detected an open window.
KEYPAD LOCK
It is possible to lock the keypad to prevent accidental modifications.
To activate the function, press the "Mode" and "+" keys together and hold
them both down until the icon appears on the display.
To unlock the keypad, press the same two keys together as before. The
"Keypad Lock" icon will no longer appear on the LCD.
IMPORTANT: The "Keypad Lock" function does not inhibit the "Standby"
key. This is therefore always active, even when the "Keypad Lock" function
is enabled.
DAY OF THE WEEK AND TIME SETUP
To enter in the daytime setup the are two possibilities:
1. Changing the batteries in the RC
2. In Chrono mode by pressing key
The default year, 2019, (from a change of batteries) or the previous set up
year (from the pressing of key) blinks on the display. The year can
be selected by the "+" or "-" keys, and confirmed by
The default month, January, (from a change of batteries) or the previous
set up month (from the pressing of key) blinks on the display. The month
can be selected by the "+" or "-" keys, and confirmed by
The default day of month (number) and day of week (the arrow), Monday,
(from a change of batteries) or the previous setups (from the pressing
of key) blinks on the display. The day can be selected by the "+" or "-"
keys (the number change and consequently also the position of arrow
changes), and confirmed by
After the day confirmation the RC exits and goes to the previous mode
(Standby in case 1 or Chrono in case 2).
Waiting a time T without touching any keys, in this case the update of
daytime won't be completed and the changes won't be saved.
The hour will be updated according to the seasonal change of the hour.
TEMPERATURE SET POINT CHANGE
In the event that the set temperature was not in use that perceived in the
centre of the room and can be modified compensation parameters of
± 2°C.
Taking a practical example if the temperature set on the thermostat is
24°C but stops heating the environment when you detect only 22°C.
The bed parameter can be corrected by -2°C.
icon stops flashing.
for several seconds.
key
key.
key.
This parameter can be changed from RC in stand-by, keeping the
mode key
pressed press the ok
RESET
To return the remote control to the factory setting press + and – in
stand-by mode.
LED ON LED OFF
There are a possibility to put the led in off. Press the key
same time in stand-by mode.
In the display are show L ON with the key + you can shift to L OF.
If the L OF is activate the led of the power unit work only for 15 seconds.
When this function is activate the first touch of the
is only to show the current function.
POWER MODULE
STAND-BY
In "Standby" mode the 2 LEDs are white.
All the operating modes are suspended ("Pilot Wire" included), but the
appliance is powered and waiting for command reception. To turn on
or off the appliance, press the "Standby" key. The radiators turns on in
"COMFORT FROM POWER MODULE" operating mode and emits a beep.
The entry into "Standby" mode is signalled by means of a double beep, the
exit from "Standby" mode by means of a long beep.
COMFORT
The "Comfort FROM POWER MODULE" temperature corresponds to 19°C.
All "Pilot Wire" commands are disabled.
The LED 1 is violet flashing.
This function allows you to use the radiator even without a remote control.
BOOST
The "Boost FROM POWER MODUL" temperature corresponds to 22°C. All
"Pilot Wire" commands are disabled.
This function allows you to use the radiator even without a remote control.
BOOST 4H : Single pressure <2 seconds of the
for 4h. In these 4H the room temperature must never exceed 22 ° C. If
exceeded the equipment will go to the off .
It must be indicated with a LED 1 Green Dark and LED 2 Violet and four
signal acoustic.
After the first start-up the equipment will turn on every day an hour earlier
according to the following scheme.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 H
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 H
BOOST 6H : Single pressure 2s<T<5s seconds of the
BOOST for 6h. In these 6H the room temperature must never exceed 22°C.
If exceeded the equipment will go to the off.
It must be indicated with a LED 1 Green Light and LED 2 Violet and four
signal acoustic.
After the first start-up the equipment will turn on every day an hour earlier
according to the following scheme.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 H
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 H
BOOST 8H : Single pressure T>5s seconds of the
for 8h. In these 8H the room temperature must never exceed 22°C. If
exceeded the equipment will go to the off.
It must be indicated with a LED 1 Red and LED 2 Violet and four
signal acoustic.
33
27
button three times.
and + at the
key in the power unit
key activates a BOOST
key activates a
key activates a BOOST
22°
19°
22°
19°
22°
19°
22°
19°