Technical data
INFORMATION REQUIREMENTS FOR ELECTRIC LOCAL SPACE HEATERS
TYPE OF HEAT OUTPUT/ROOM TEMPERATURE CONTROL
Single stage heat output, no room temperature control
Two or more manual stages, no room temperature control
With mechanic thermostat room temperature control
With electronic room temperature control
Electronic room temperature control plus day timer
Electronic room temperature control plus week timer
OTHER CONTROL OPTIONS
Room temperature control, with presence detection
Room temperature control with open window detection
With distance control option
With adaptive start control
With working time Iimitation
With black bulb sensor
TROUBLE SHOOTING
The appliance does not heat up.
The appliance heats continuously.
The room stays cold.
Leaks of the liquid in the appliance.
The appliance does not respond
correctly to orders received from the
Pilot Wire control unit.
The appliance keeps on heating despite
the window is open and the "Open
Window" function is active.
The appliance does not resume heating
after the window is closed and the
"Open Window" function is active.
The display shows "ALL".
Check if the radiator is correctly connected to the mains power grid and powered.
Check the position of the mains switch of the installation.
Increase the temperature set point on the appliance regulator.
The safety device has tripped. Eliminate the cause of overheating (for example,
obstructions or covering).
Disconnect the appliance from the household mains for a few minutes to reset the
electronic system.
If it still does not heat up, contact your local dealer or a qualified professional.
Reduce the temperature set point on the appliance regulator.
Make sure the "Overdrive (2h)" function has not been activated accidentally.
If it continues to heat, contact your local dealer or a qualified professional.
Make sure the power of the appliance is adequate for the room to be heated.
If the appliance is being used for the first time, the room takes at least a couple of hours to heat to the
required temperature (setting the radiator to maximum does not raise the temperature more quickly).
Turn the appliance off and contact your local dealer.
Dry the leaks using gloves to protect from the chemical products. Keep children and pets away from the
liquid.
Disconnect the appliance from the mains power supply (switch off the mains switch by moving it in the "0"
position). Make sure the connection is correct and the control unit is functioning correctly.
Contact a qualified professional.
It may be necessary to wait a few minutes before the function starts operating.
The difference between the outside and inside temperature may not be sufficient to acti vate the function.
Check that the positioning of the appliance comply with the requirements referred to in this
booklet.
Check that the area around the appliance Command is free of any obstacles.
If the problem persists, contact your dealer or qualified personnel.
It may be necessary to wait a few minutes before the sensor detects the window closing.
Check that the area around the appliance Command is free of any obstacles.
Deactivate and activate the function again.
Should the response time of the function be too long, you can switch the radiator on manually at any time.
If the problem persists, contact your dealer or qualified personnel.
The temperature sensor is malfunctioning. Turn the appliance off and contact your local dealer.
24
21
NO
NO
NO
NO
NO
YES
NO
YES
NO
YES
NO
NO