Installation
ELECTRICAL CONNECTION
•
To be installed by a specialised engineer in accordance with the
applicable standards in the country concerned.
•
When the appliance is installed, make sure the power is off and the
mains switch is in the "O" position.
•
The appliance requires a 230 V ~ 50 Hz power supply. Make sure
the power line is appropriate for the data shown on the appliance's
rating plate.
HEIGHT
LENGTH
1194mm
616mm
1194mm
616mm
Product Information:
Voltage : 230 V~ 50 Hz
Class of protection : II
Indice of protection: IP34
Make sure the fixed power line is fitted with a disconnecting switch
allowing the appliance to be disconnected completely from the household
mains in accordance with the wiring rules.
DO NOT wire/fit a plug to this appliance. The appliance must be electrically
connected to a fused fixed spur, which is fitted with a 13Amp fuse.
All fittings must be installed by a competent person in accordance
with the current IET Wiring Regulations (BS7671). If in doubt, consult a
qualified electrician.
This product is suitable for use in living areas, and Bathroom (dry) outside
Zones and zone 2 only (see diagram below and current IET Wiring
Regulations for details). It is not suitable for Bathroom Zones 0 and 1. If
being fitted in a bathroom a 30mA RCD must be used. This appliance does
not come fitted/supplied with a fused plug.
Always refer to the Reference Drawing for Bathroom Installation.
Note: the below drawing is for reference only.
(DRY) OUTSIDE ZONES
ZONE
1
0.6m
2.25m
ZONE
0
IP34: THIS PRODUCT IS SUITABLE FOR BATHROOMS
(DRY) OUTSIDE ZONES AND ZONE 2
Permanently connected appliances must be connected using a connector
block placed within a proper junction box.
When installing the appliance in damp rooms (kitchen, bathroom), the
point of connection with the household mains must be at least 25 cm from
the floor.
If the Pilot Wire is not connected to the programming unit, it must be
terminated and insulated. Under no circumstances should the Pilot Wire be
connected to the earth.
Make sure the power cable cannot in any way come into contact with the
surface of the appliance.
WIDTH
POWER
120mm
500W
120mm
350W
Ceiling
0.6m
ZONE
2
A
2,2
1,5
29
23