Electronic Control; Pinouts - Whirlpool LHW0050PQ Mode D'emploi

Table des Matières

Publicité

ELECTRONIC CONTROL

F1
Receives power from the ON-OFF button.
F2
Feeds door catch contact BP3.
F3
Current output to ON-OFF button.
F4
Feeds pressure switch contact P11.
F5
Feeds the heating element through the internal safety thermo-fuse.
F6
N/A
F7
Receives the pressure switch level reached signal from contact P14.
F8
Feeds door catch contact BP1.
F9
N/A
F10
Feeds door catch contact BP2.
F11
Receives the return signal from the washing heating element through safety thermostat T90⋅C which,
when the temperature is reached, opens the contact.
F12
N/A
B1-B3 Feeds Hot Water Solenoid Valve EVH.
B1-B2 Feeds Cold Water Solenoid Valve EVC.
B4
Common Thermo-actuator A and Thermo-actuator B.
B5
Power supply Thermo-actuator A (wash).
B6
Power supply Thermo-actuator B (softener).
B7-B8 Power supply Drain Pump.
B9
Return signal from Pressure Switch Overfill Safety (P16), starts the pump.
B10
Common Drying Water Solenoid Valve (EVA) and Drying Fan Motor (VA-BL1).
B11
Power supply Drying Water Solenoid Valve (EVA).
B12
Power supply Drying Fan Motor (VA-BL2) and Drying Fan Motor Capacitor (VA-C).
M1-M2-M3-M4-M5
Power Supply Motor.
M6-M7
Return signal from thermistor.
S1-S2
Receives signal from program selector potentiometer.
Flat Cable
Receives information from the pushbutton circuit board (wash options).

PINOUTS

1
12
Connector B
1
1
7
Connector M
Con. S
6-7
6-7
6-7
6-7
6-7
4

Publicité