PROBLEM
TEST
- Check that the solenoid valve is working by carrying out
the appropriate test for that particular component.
- Check that the pressure switch is working by carrying
Water
out the appropriate test for that particular component.
flows into
- Check that there are no leaks from the tub unit.
the tub
continu-
- Remove the pressure switch pipe from the drain cou-
ously
pling and check that there are no holes in the pipe.
- If all the above tests result negative, replace the con-
trol unit.
After eight failed attempts to start the motor (either in wash
or spin mode), the control unit passes to the end of the
cycle, and the End indicator light flashes (motor rotor
blocked or tachometric open).
If the control unit does not detect the pressure switch
Safety
empty condition after twenty minutes of pump running time,
it passes to the next step (pump blocked).
If, after fifty minutes of heating element operation the set
temperature has not been reached, the control unit ad-
vances, and continues the cycle as normal.
6-6
6-6
6-6
6-6
6-6