Débranchez l'appareil avant la réoaration.
Replacez toutes les pièces et panneaux d'accès avant de faire fonctionner.
Danger de choc électrique ou de mort.
WATER INLET VALVES
Refer to page 4-8 for the procedure for servic-
ing the water inlet valves.
1.
Unplug washer or disconnect power.
2.
Disconnect the wire connectors from the
water inlet valve you are testing.
3.
Set the ohmmeter to the R X 1 scale.
4.
Touch the ohmmeter test leads to the
water inlet valve solenoid terminals. The
meter should indicate between 75 and
125 Ω.
WARNING
Danger de choc électrique
DOOR SWITCH
1
3
2
Refer to page 4-10 for the procedure for servic-
ing the door switch.
1.
Unplug washer or disconnect power.
2.
Disconnect the wire connectors from the
door switch terminals.
3.
Set the ohmmeter to the R X 1 scale.
4.
Touch the ohmmeter test leads to door
switch terminals 1 and 3. The meter should
indicate between 650 and 850 Ω.
5-3
5-3
5-3
5-3
5-3
1
650-850 Ω
3
2