16-72X
- Plug the mini jack of the IR-receiver (16-720) into the connection on the IR-connection block
(16-724) labelled 'IR RCVR'.
- Connect the power supply block (16-725) to the IR-connection block labelled '12V DC'.
The system is now ready for use.
Control of the Niko audio distribution system A44 or A88 via IR
It is also possible to control the Niko audio distribution system A44/A88 via the IR-signal distribution
system. To do this, connect one of the outputs of the connection block (16-724) labelled EMITTERS
to the 2 terminals of the 'Direct Infrared' input of the A44 or A88 audio distribution system.
Remarks concerning installation and use
- In some cases, plasma screens can emit undesired IR-interference signals. This could disturb
the IR-reception of the IR-receivers 16-720 to 16-723. You should therefore carefully consider
where you place the IR-receivers.
EN
87