16-72X
ATTENTION: The 'BL-ON'-position will set the corresponding outputs to 'high
power'. Make sure the dipswitch is in 'EM ON'-position when using the mini IR-
transmitter (16-727 or 16-728). Noncompliance with this setting can irreversably
damage the connected mini IR-transmitter.
6. 12VDC Regulated: connection for 16-725 12VDC power supply. The pin in the middle is
+12V.
7. STATUS IN 5-24VDC: 2.1mm DC jack for the connection of 5-24 V DC. Used for the con-
nection of the status LEDs of the IR-receivers (16-720 to 16-723).
8. IR RCVR: Connection for the 4-pole mini jack of the IR-receivers (16-720 to 16-723).
The connection block (16-724) with its power supply (16-725) is best installed in the imme-
diate vicinity of the audio and video installation to be controlled. The connection block can
be secured with 2 screws, for example, in the piece of furniture or rack where the sound
equipment is located.