3. Wall Control Installation
3.7
Connect the Wall Control BLACK
wire to the Fan/Motor Lead (BLACK
or RED) wire using a new wire
connector (supplied).
NOTE:
Use
connectors supplied with the new
wall control to secure electrical
connections.
3.8
Connect the Wall Control BLACK
wire to the 120 VAC source hot
BLACK wire using a new wire
connector (supplied).
3.9
Securely
connect
ground wire from the Wall Control to
the supply ground wire (bare or
green).
WARNING
!
Check
to
see
connections are tight, including
ground, and that no bare wire is
visible at the wire connectors,
except for ground.
only
the
wire
the
GREEN
that
all
wire
(Continued)
FAN/MOTOR
WIRE
BLACK OR RED
CONNECTOR
WIRE
WALL CONTROL
BLACK WIRE
WALL CONTROL
WIRE CONNECTOR
WALL CONTROL
BLACK WIRE
120 VAC HOT
BLACK WIRE
WALL
CONTROL
WALL CONTROL
GREEN
GROUND WIRE
WIRE
CONNECTOR
6
U.L. Model No.: SW93/SW95/SW96
TO FAN
MOTOR LOAD
TO 120VAC
SOURCE HOT
TO FAN
MOTOR LOAD
TO 120VAC
SOURCE HOT
SUPPLY
GREEN
GROUND
WIRE