BP7499 SW93 SW95 SW96.qxp_Layout 1 12/1/14 2:39 PM Page 4
The SW93 & SW96 Wall Controls
are designed to operate multiple
ceiling
fans,
accessory light kits.
The
SW95
designed to operate only one
ceiling fan, and Not an accessory
light kit.
The SW93 / SW95 / SW96 Wall
Controls do not require a receiver.
The SW93 Wall Control is rated for
3.0 Amp, 120 VAC, 60 HZ full load.
The SW95 Wall Control is rated for
1.25 Amp, 120 VAC, 60 HZ full
load.
The SW96 Wall Control is rated for
5.0 Amp, 120 VAC, HZ full load.
Installation of Wall Control
replacing an Existing Wall
Control:
3.1
Disconnect electrical power to the
branch circuit at the circuit breaker
or fuse box before attempting to
install the ceiling fan mounting plate
on the outlet box.
NOTE: The ceiling fan must be set
at the highest speed setting
before installation of the Wall
Control.

2. General Information

and
Not
any
Wall
Control
is

3. Wall Control Installation

To avoid erratic speeds and
possible damage to your ceiling
fan, use the Wall Control only with
fans pull chain switches set to
their high speed settings.
All
ceiling
fans
completely
installed
installation of the Wall Control.
Your new Wall Control will require
a grounded electrical supply line
of 120 volts AC, 60 HZ circuit.
WARNING
!
Turning off wall switch is not
sufficient.
To
electrical shock, be sure electricity
is turned off at the main fuse box
before wiring. All wiring must be in
accordance with National and Local
codes and the ceiling fan must be
properly grounded as a precaution
against possible electrical shock.
4
U.L. Model No.: SW93/SW95/SW96
must
be
before
avoid
possible

Publicité