uk │ 2. Product information
2.7 Description of Maico Smart,
network with radio electronic unit
Network
Slave fan
(max. 2)
Window
contact
(max. 2)
Maico Smart with ECA150 ipro units
● Receivers are ECA 150 ipro fans in the
RC, RCH, KRC or KRCH models.
● Transmitters are system components
such as the room air control RLS RC,
radio switch DS RC, wireless window
contacts and ECA 150 ipro fans in the RC,
RCH, KRC or KRCH models.
● All ECA 150 ipro RC models in the
network can be combined with each other.
● RCH and KRCH units also with humidity
control ( Chapter 2.6).
● The system can be operated with a radio
switch and /or RLS RC:
● Per radio switch, 2 performance levels
can be selected, or the system can be
switched off.
● With the RLS RC 3 room air control
system levels can be switched on manu-
ally ( table in Chapter 9). Ex works, this
function is deactivated in order to guaran-
tee continuous ventilation. If need be, this
function can also be activated ( moun-
ting instructions RLS RC).
● With window radio contacts (window open/
closed), the fan can also be switched
on/off.
● When the unit is first used the transmitters
must be set up on the receivers (so the
receivers recognise them).
20
Single unit
Radio switch
(max. 5)
Radio switch
(max. 5)
Fan
(Master)
Controller
RLS RC
2.8 Other wireless components
2.8.1 DS RC radio switch
EnOcean switch, optional
The DS RC radio switch (double rocker
switch) changes the fan performance level
up or down.
The left and right rockers must be set up
separately. The left rocker is for on/off and
the right rocker switches the level up or down.
The radio switch is always taught in the room,
where the fan is installed.
Radio switch in master/slave network
The ventilation system operates as specified
on the room air control RLS RC. When a
radio switch is operated the assigned fan
switches to the manually selected
performance level (this takes priority over the
automatic system).
After approx. 30 minutes (timeout), the device
returns to the setting according to RLS RC.
If the setting on the RLS RC changes during
this 30-minute period, the assigned fan
does not react to this command until the
30 minutes have elapsed.
In RCH/KRCH units the automatic humidity
process has priority. The fan cannot be
operated with the RLS RC, DS RC or window
contact during humidity operation.
* to be
provided
by customer
Window
contact*
(max. 2)