cegard/Mini-MOD
4.4
Dynamic mounting
The following figure provides an overview of the installation of the cegard/Mini-MOD in an elevator application. Additional
details are provided in the mounting kit manuals.
Figure 7:
Mounting example for an elevator door protection application
4.5
Installation of the UPS (Universal Power Supply)
The UPS can be mounted horizontally or vertically with four screws near the door drive. The mounting is backwards
compatible with the cegard/Max controller.
Figure 8:
Mounting possibilities of the UPS
6
NOTICE
 Ensure that the cable bending radius is greater than 80 mm when
cables are mounted.
 If the cables are not properly fixed and guided, their lifetime could
be reduced drastically. They can also be damaged due to possible
swinging and snagging in the hoistway! Always follow the cable
guide instructions carefully, which can be found in the appropriate
mounting kit installation and operation manual.
 It is very important to install cables properly to ensure the highest
possible reliability and lifespan of the light curtain. A properly
installed cable will withstand more than 20 million door movements,
while a poorly installed cable could break after less than 100,000
door movements.
Interface
Rx
connector
Tx
NOTICE
The recommended distance between
the door sill and the bottom of the
sensor is 7 mm to 11 mm. A greater
distance reduces safety due to an
unprotected area right above the sill.
English
© CEDES | V 2.2