Operation; Applications; Before Starting The Generator - PowerSmith PGA2200i Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

APPLICATIONS

This generator is designed to supply electrical power to electrical devices, including lights, appliances, tools, and etc.

BEFORE STARTING THE GENERATOR

WARNING:
Read and understand the Important Safety Rules before starting the generator.
Location Selection
– To avoid exhaust and location hazards, select location with following conditions.
Outdoors and well ventilated.
A level and solid surface on which to place the generator.
At least 20 feet away from any building, other equipment or combustible material. If the generator is located close to
a building, make sure it is not located near any windows, doors and/or vents.
DANGER:
Using a Generator Indoors CAN KILL YOU IN MINUTES. Generator Exhaust Contains Carbon
Monoxide. This is a poison you cannot see or smell. NEVER use inside it in a home or garage, even if doors and windows
are open. Only use OUTSIDE and FAR AWAY from windows, doors, and vents.
WARNING:
Always operate the generator on a level surface. Placing the generator on nonlevel surfaces
can cause the generator to tip over, causing fuel and oil to spill. Spilled fuel can ignite if it comes in contact with an
ignition source such as a very hot surface.
Weather
Never operate the generator outdoors during rain, snow or any combination of weather conditions that
could lead to moisture collecting on, in or around the generator.
No Attached Loads
– Make sure the generator has no attachedd loads before starting it. To ensure there are no
attached loads, unplug any electrical extension cords that are plugged into the control panel outlets.
CAUTION:
Starting the generator with loads already applied to it could result in damage to any appliance being
powered off the generator during the brief start-up period.
Grounding the Generator
WARNING:
To prevent electrical shock from faulty appliances, the generator should be grounded.
Connect a length of heavy wire between the generator's ground terminal and an external ground source.
CHECKING / ADDING ENGINE OIL
Be sure to check the oil level before each use with the generator on a flat, level surface and the engine stopped.
WARNING:
Health studies have shown that chemical exposure may cause potential human health risks.
Take care when handling oil. Avoid direct contact with skin. Wash contact areas with soap and water. When contacted
with eye, flush thoroughly with water. If irritation occurs, get medical assistance.
Always use 4-stroke motor oil that meets or exceeds the requirements
for API service classification SJ. 10W-30 is recommended to for general,
all-temperature use. Other viscosities show in the chart (FIG 6) may be
used when the average temperature in your area is within the indicated
range.
CAUTION:
Do NOT use non-detergent oil or 2-stroke engine oil,
it could shorten the engine's service life.
1.
Placed the generator on the level surface.
2.
Loosen the cover screws and remove the maintenance cover. See Fig 7.
3.
Unscrew the oil cap/dipstick and remove. Wipe the dipstick clean.
4.
Check the oil level by re-inserting the dipstick into the filler neck without screwing it in.
5.
If the oil level is low, refill to the level between the minimum and maximum mark on the dipstick with the
recommended oil.
English

OPERATION

– Consult with a qualified local electrician for grounding requirements in your area.
13
FIG 6

Publicité

Table des Matières
loading