Ground Terminal; Spark Arrester - PowerSmith PGA2200i Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

KNOWING YOUR GENERATOR
DC OUTLET --
Provides 12V DC power up to 7.5A. The DC outlet should only be used for charging 12 volt
automotive-type batteries.
AC OUTLET --
Your generator has two outlets that provide 120V, 60Hz AC power up to 14.17A. These can be used
for operating the appliances, electrical lighting, tools, and other motor loads.
USB PORT --
The two 5V 2.0A USB charging ports will charge most USB-compatible devices.
AUTO IDLE SWITCH --
When Auto Idle is on and no appliances are connected to the unit, the engine will idle. If a device is added, the engine
speed will increase to power the device. If the device is removed, the engine will return to idle.

GROUND TERMINAL --

protect against electrical shock. Consult with a qualified local electrician for grounding requirements in your area.
ENGINE SWITCH --
the choke and the fuel valve.
RECOIL STARTER --
RESET BUTTON --
all loads and depress the reset button.
PARALLEL KIT TERMINALS --
included) that will allow generators to be linked together to increase power output.
FUEL CAP --
Remove the fuel cap to check and refill the fuel when needed.
FUEL TANK VENT --
OIL CAP / DIPSTICK --
FUEL LEVEL INDICATOR --
DIGITAL DISPLAY SCREEN --
Wattage, Running Hours, Amps, and Engine Revolution Speed.
OUTPUT INDICATOR --
OVERLOAD INDICATOR --
OIL ALARM INDICATOR --
and add engine oil.

SPARK ARRESTER --

servicing. Avoid contact until the engine is cooled down.
English
The auto idle switch is used to control the speed of the engine and conserve fuel.
The ground terminal is used to assist in properly grounding the generator to help
The engine switch is used when starting, stopping, and running the engine. It also controls
The recoil starter is used (along with the Engine Switch) to start the generator's engine.
The reset button is used to restore power if an overload occurs. To restore power, remove
The non-polarized parallel kit terminals are used with a parallel kit (Not
Open vent to run the engine, and close the vent when the engine is off
Remove the oil fill cap to check and add engine oil to the generator when necessary.
Indicates how much fuel remaining in the fuel tank.
Displays the real time load and data, including Voltage, Frequency,
Light turns green during normal operating conditions.
Red or Red Flashing light indicates the loads are over the generator's capacity.
Red light Indicates the engine oil level is below the safe limit. It is time to check
The spark arrestor prevents sparks exiting from the muffler. It must be removed for
12

Publicité

Table des Matières
loading

Table des Matières