7 Specifications
GB
General
Display: . . . . . . . . . . . . . . . 15 mm LCD, 3
Measuring rate: . . . . . . . . . 2.5 measurements per secund
Power supply: . . . . . . . . . . 1 x 9 V transistor battery
Operating range: . . . . . . . . 0 – 40 °C, < 70 % relative humidity
Voltage
Measuring ranges (V~/ ): 200 mV, 2000 mV, 20 V, 200 V, 600 V
AC voltage frequency range: 50 – 500 Hz
Accuracy*
Direct voltage: . . . . . . . . ±(0.8 % + 1 digit)
AC voltage: . . . . . . . . . . ±(1.5 % + 3 digits) for the ranges
Input resistance: . . . . . . . . 10 MΩ
Overload protection: . . . . . 600 V~/
Current
Measuring ranges (A~/ ): 200 µA, 20 mA, 200 mA, 10 A
AC current frequency range: 50 – 500 Hz
Accuracy*
Direct current: . . . . . . . . ±(1.0 % + 1 digit) for the ranges from
AC current: . . . . . . . . . . ±(2.0 % + 4 digits) for the ranges
Fuse: . . . . . . . . . . . . . . . . . 1 x 0.5 A/250 V, super-quick-acting
18
1
from 200 mV to 20 V
±(2.0 % + 3 digits) for the ranges
200 V and 600 V
max.
200 µA to 200 mA
±(3.0 % + 3 digits) for the range 10 A
from 200 µA to 200 mA
±(3.5 % + 4 digits) for the range 10 A
1 x 10 A/600 V, super-quick-acting
/
digits
2