Troubleshooting - Astralpool PRO ELYO TOUCH PET-08 Manuel D'installation Et D'utilisation

Table des Matières

Publicité

8.1 Error code display on LED wire controller
Malfunction
Inlet water temperature
sensor failure d1-TH6
Outlet water temperature
sensor failure d2-TH5
Heating piping sensor failure
d5-TH2
Ambient temperature sensor
failure d3-TH1
Exhaust piping sensor failure
d6-TH3
Antifreeze protection in
Winter
Low ambient temperature
protection
Piping temperature too high
protection under cooling
mode d5-TH2
Over low protection for
outlet water temperature in
cooling mode d2-TH5
High pressure failure TS4
8.
8.
8.

Troubleshooting

Troubleshooting
Troubleshooting
Error
Reason
code
1. The sensor in open or short circuit
PP01
2. The wiring of sensor is loose
1. The sensor in open or short circuit
PP02
2. The wiring of sensor is loose
1. The sensor in open or short circuit
PP03
2. The wiring of sensor is loose
1. The sensor in open or short circuit
PP05
2. The wiring of sensor is loose
1. The sensor in open or short circuit
PP06
2. The wiring of sensor is loose
Ambient temperature or water inlet
PP07
temperature is too low
1. Out of the normal operating
ambient temperature for this
PP08
machine by checking d3
2. Sensor abnormality d3-TH1
1. Ambient or the water temperature
is too high in cooling mode
PP10
2. Refrigeration system is abnormal
3. Pipe temperature sensor(d5-TH2)
failure
1. Low water flow
2. Outlet water temperature sensor
d2-TH5 abnormal
PP11
3. The difference of outlet water
temperature and set temperature is
7 ℃ or above in cooling mode
1. Ambient temperature is too high
2. Water temperature is too high
3. Water flow is too low
4. Fan motor speed is abnormal or
fan motor is damaged under cooling
EE01
mode
5. Gas system jammed
6. High pressure wire is loose or
damaged
7. Too much refrigerant
1. Check or change the sensor
2.Re-fix the wiring of the sensors
1. Check or change the sensor
2.Re-fix the wiring of the sensors
1. Check or change the sensor
2.Re-fix the wiring of the sensors
1. Check or change the sensor
2.Re-fix the wiring of the sensors
1. Check or change the sensor
2.Re-fix the wiring of the sensors
1. Check the d1((inlet water temp.) and
d3(outlet water temp.)
2. Normal protection
1. Stop using, beyond the scope of using
2.Change the sensor
1. Check the ambient temperature
2. Check refrigeration system
3. Change the pipe temperature sensor
(d5-TH2)
1. Check filtration pump and waterway
system
2. Change outlet water temperature
sensor d2-TH5
3. Change the set temperature.
1. Choose the silent mode.
2. Check the water flow or filtration pump
3. Check the fan motor under cooling
mode, replace a new one if it is abnormal.
4. Check and repair the refrigerating
system
5. Reconnect the high pressure wire or
replace a new high pressure switch
6. Check and repair the refrigerating
system