Performance Data Sheets - Jennair JFC2089BEM Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Model EDR4RXD1/EDR4RXD1B (equivalent to UKF8001)
This system has been tested according to NSF/ANSI Standards 42, 53, 401 and CSA B483.1 for the reduction of the substances
listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or
equal to the permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42, 53, 401 and CSA B483.1.
Substance Reduction
Influent Challenge
Aesthetic Effects
Concentration
Aesthetic Effects
Concentration
Chlorine Taste/Odor
2.0 mg/L ± 10%
Particulate Class I*
At least 10,000 particles/mL
Influent Challenge
Contaminant
Concentration
Reduction
Concentration
Lead***: @ pH 6.5 / @
0.150 mg/L ± 10%
pH 8.5
Mercury: @ pH 6.5 / @
0.006 mg/L ± 10%
pH 8.5
Asbestos
10
Cysts
50,000/L min.
Atrazine
0.009 mg/L ± 10%
Benzene
0.015 mg/L ± 10%
Carbofuran
0.080 mg/L ± 10%
Lindane
0.002 mg/L ± 10%
P-Dichlorobenzene
0.225 mg/L ± 10%
Tetrachloroethylene
0.015 mg/L ± 10%
Toxaphene
0.015 mg/L ± 10%
Atenolol
200 ± 20%
Endrin
0.006 mg/L ± 10%
Ethylbenzene
2.1 mg/L ± 10%
O-Dichlorobenzene
1.8 mg/L± 10%
2,4 - D
0.210 mg/L ± 10%
Carbamazepine
1400 ± 20%
DEET
1400 ± 20%
Linuron
140 ± 20%
Meprobamate
400 ± 20%
Metolachor
1400 ± 20%
Trimethoprim
140 ± 20%
Bisphenol
2000 ± 20%
Estrone
140 ± 20%
Nonylphenol
1400 ± 20%
Ibuprofen
400 ± 20%
Naproxen
140 ± 20%
Phenytoin
200 ± 20%
Turbidity
11 NTU ± 10%
Chlorobenzene
2.0 mg/L ± 10%
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.70 gpm (2.65 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 200 gallons (757 liters).
The compounds certified under NSF 401 have been deemed as "emerging compounds/incidental contaminants." Emerging
compounds/ incidental contaminants are those compounds that have been detected in drinking water supplies at trace levels. While
occurring at only trace levels, these compounds can affect the public acceptance/ perception of drinking water quality.
18
PERFORMANCE DATA SHEET
Water Filtration System W11256135 and W11311161
Capacity 200 Gallons (757 Liters) with PID.
100 Gallons (379 Liters) without PID.
System tested and certified by NSF International against NSF/
ANSI Standard 42, 53, 401 and CSA B483.1 for the reduction of
contaminants specified on the Performance Data Sheet.
to 10
fibers/L
7
8
††
Maximum Permissible
Product Water
Concentration
Concentration
50% reduction
85% reduction
Maximum Permissible
Product Water
Concentration
0.010 mg/L
0.002 mg/L
>99%
>99.95%
0.003 mg/L
0.005 mg/L
0.040 mg/L
0.002 mg/L
0.075 mg/L
0.005 mg/L
0.003 mg/L
30 ng/L
0.002 mg/L
0.7 mg/L
0.6 mg/L
0.07 mg/L
200 ng/L
200 ng/L
200 ng/L
60 ng/L
200 ng/L
20 ng/L
300 ng/L
20 ng/L
200 ng/L
60 ng/L
20 ng/L
30 ng/L
0.5 NTU
0.1 mg/ L
Minimum %
Average% Reduction
Reduction
>97.4%
97.4%
99.3%
99.0%
Minimum %
Average%Reduction
Reduction
99.6% / >99.7%
99.3% / >99.7%
96.3% / 94.5%
96.3% / 89.5%
>99%
>99%
>99.99%
99.99%
>94.3%
94.3%
>96.5%
96.5%
>98.8%
98.8%
>99.0%
98.9%
>99.8%
99.8%
>96.4%
95.8%
>93.2%
93.1%
>95.5%
95.5%
96.4%
94.8%
>99.9%
99.9%
>99.9%
99.9%
99.3%
97.4%
>98.7%
98.6%
>98.6%
98.6%
>96.3%
96.3%
>95.2%
95.2%
>98.7%
98.7%
>96.6%
96.5%
>99.1%
99.1%
>96.6%
96.4%
>96.7%
96.6%
>95.5%
95.3%
>96.8%
96.7%
>95.5%
95.5%
98.8%
98.2%
>99.9%
99.9%

Publicité

Table des Matières
loading

Table des Matières