NOISE LEVELS
The machine's noise level was measured in accordance with the EN 709 standard by the Institute
of Agricultural Engineering, Bologna University.
The noise levels were measured using a Bruel & Kjaer measuring device, serial number 1178097,
complying with IEC804, IEC651-1I, ANSI S1.4-1983 and a B&K microphone complying with IEC651.
The noise levels were measured in an area free from obstacles over a radius of at least 20 m. and
with the engine at normal operating temperature.
The data given below refer to draft standard CEE PrEN 1553: 1994-annex B.
Ambient pressure 760 mmHg;
Temperature 3°C;
Relative humidity 85%;
Wind speed below 0.5 m/s (and thus the correction constant due to background noise is equal to
zero).
11500 MOTOR HOE
Equivalent acoustic pressure level in the driving position [db(A)]
1)
90.1
VIBRATION LEVELS
The vibrations levels were measured by the Institute of Agricultural Engineering, Bologna University.
in accordance with the draft standard CEN PrEN 709: 1994 and standard 1033.
The weighted mean hand acceleration values calculated under the ISO standards are shown in
the table below:
Ambient conditions:
Ambient pressure 770 mmKg;
Temperature 11°C;
Relative humidity 92%;
11500 MOTOR HOE
Engine speed:
3600 rpm nominal without load, and 3060 during the test
Forward direction
Transverse direction
Vertical direction
a
eq
TIPPING ANGLE
2)
90.1
Engine speed 3060 rpm
(noisiest side Left).
3)
89.9
10
conventional mean
90.1
a
[m/s
2
]
hw
1,85
3,16
5,42
6,54