Other Mode
Ω @ 25°Celsius
°Fahrenheit
Ohm (Ω)
14°F
55076Ω
32°F
34603Ω
50°F
22284Ω
68°F
14675Ω
86°F
9860Ω
OCD6-1999
Instruction
English
FIG. 1 - CONTENT
• Thermostat
• Sensor
The thermostat is an electronic PWM/PI thermostat for temperature
control by means of an NTC sensor located either externally or
internally within the thermostat.
The thermostat is for flush mounting in a wall socket.
This thermostat can be used as a controller for electric room heating
pursuant to EN50559.
Product programme
OCD6-1999
Clock-thermostat with two sensors:
floor sensor and built-in room sensor.
FIG. 2 - WARNING – Important Safety Instructions
Disconnect the power supply before carrying out any installation or
maintenance work on this thermostat and associated components.
The thermostat and associated components should only be installed
by a competent person (i.e. a qualified electrician). Electrical instal-
lation must be in accordance with appropriate statutory regulations.
FIG. 3 - THERMOSTAT PLACEMENT
Mounting of sensor
The floor sensor contains a safety extra-low voltage (SELV) circuit,
allowing it to be placed as close to the floor surface as possible
without having to take account of the risk of shock should the sen-
sor cable become damaged. The two wires connecting the sensor
to the mounting box must be additionally insulated, e.g. shrink flex.
To prevent loose wires in the fixed installation from coming into
contact with the terminal block for the floor sensor, they must be
restrained using cable ties.
It is strongly recommended that the cable and sensor are placed in
a non-conductive installation pipe embedded in the floor. The end of
© 2016 OJ Electronics A/S