Setting values for OP
LK8122
cm
inch
6.9
8.2
9.4
10.6
11.8
13.0
14.3
15.5
16.7
17.9
19.1
20.4
Setting range for SPx, rPx
LK8122
cm
SPx
2.5...19.0
rPx
2.0...18.5
ΔL*
0.5
*ΔL = increments
rPx is always smaller than SPx, SPx is always smaller than OP.
If the value for OP is reduced to a value ≤ SPx, the position of SPx is shifted.
Reducing the value for SPx to a value ≤ rPx also shifts the position of rPx.
If the difference between rPx and SPx is small (approx. 3 x increment),
increasing rPx also increases SPx.
If the difference between rPx and SPx is great, rPx remains at the set value
even if SPx is increased.
cm
2.7
13.9
3.2
16.3
3.7
18.8
4.2
21.2
4.7
23.6
5.1
26.1
5.6
28.5
6.1
31.0
6.6
33.4
7.1
35.8
7.5
38.3
8.0
40.7
inch
1.0...7.4
4.0...39.0 1.6...15.4
0.8...7.2
3.5...38.5 1.4...15.2
0.2
LK8123
inch
5.5
6.4
7.4
8.3
9.3
10.3
11.2
12.2
13.1
14.1
15.1
16.0
LK8123
cm
inch
0.5
0.2
LK8124
cm
inch
20
8.0
24
9.5
28
10.9
31
12.3
35
13.8
39
15.2
42
16.7
46
18.1
50
19.5
53
21.0
57
22.4
61
23.9
LK8124
cm
inch
6...58
2.5...23.0
5...57
2.0...22.5
1
0.5
37