DOOR PANEL INSTALLATION
P
lace the nameplate
Twist the call wires as shown The call wires will be
connected to the EL500/R5 microprocessed circuit
or to the corresponding EL516SE push buttons encoder
labels.
Open the label holder
For a quality finish, pass the push buttons wires through
the spacer hole of the closest module It's recommended
to use wires between 0,1 up to 0.25mm section
.
IMPORTANT link the push buttons common terminal of
the several push buttons modules The common terminal
of the push buttons contained in a module are linked
from factory
This wire must be connected to the CP terminal of the
EL500/R5 microprocessed circuit or of the corresponding
EL516SE encoder circuit
.
.
:
.
.
105
Place the label
and close
.
P
ush buttons
wiring.
.
2
.
.