DEFINITION
The Golmar
Vista PLUS
the 4+n or conventional electronic door entry systems in both apartment blocks and villas, making
use of the existing installation Adding to this, the fact that the system does not use coaxial cable for
video signal transmission (it is transmitted via an untwisted pair of wires), necessitates a detailed
study of the existing installation before installing the system To check that your installation complies
with the system's minimum recommended requirements, please read carefully the following chapters,
which provide details of the checks to be done
MINIMUM REQUIREMENTS
Before installing this system, we must ensure that the existing installation complies with the following
requirements
:
-
All the wires of the installation must use the same conduit, especially those that carry the
video signal and ground
-
The wires must not be spliced, frayed, nor touch metal parts, and must not vary in cross
section throughout the entire installation
-
The entire installation must be at least 40cm away from any other installation otherwise
there is a risk that the audio signal be exposed to interference, or that the system does
not work correctly
-
All branch connections must be made using D4L-R5 or D4L-R5R distributors
-
Each floor must have physical space to situate the distributor/s and junction box in case of using
D4L-R5R distributors, in case they are necessary
-
Each apartment must have sufficient space to install the video system monitor
-
Maximum distance between the power supply and the farthest monitor
-
Maximum distance between the door panel and the farthest monitor
power supply's position)
-
Maximum number of terminals in total (monitors, telephones, call repeaters, etc.)
using converters)
-
Before connecting the system's power supply, we must ensure that there are
relays or call repeaters in the apartments
with units that are compatible with the new system, otherwise the installation could be seriously
damaged or burnt
If any of the first three requirements are not met, it will be necessary to replace the installation riser
If the branch connections to the apartments are in good condition, their replacement will not be
necessary
.
If replacing the backbone, use these sections
SECTIONS CHART
+, , CV+, CV
–
V+, V-, A/D
Golmar has a special cable for this system, its reference number is
ensures the correct functioning of the system and simplifies the riser replacement given that it contains
all the necessary wires for the installation
video door entry system is a digital system, specially designed to replace
.
.
.
.
.
:
Power supply - Door panel
Terminal
50m.
~1 ~2
,
1.00mm²
–,
.
.
.
.
.
. If so, we must disconnect them or replace them
Door panel - Monitors
100m.
50m.
2.5mm²
1.00mm²
0.25mm²
RAP-8415.
.
.
: 50mts
: 50/100mts
(according to
: 200
(without
NO parallel units,
100m.
2.5mm²
0.25mm²
The use of this cable