• Set the main operating parameters (e.g. installation right/left) in the options menu.
• If you have safety devices working with 8.2k contacts select the correct setting from the safety device menu.
• Before programming the gate travel distances select the correct motor in the "Motion" menu.
TEST
OK
"PROG/OK" to confirm
"PROG/OK" to confirm
T B
F I
TEST
F S
CP
PRESS ANY KEY
"PROG/OK" to confirm
BACK TO TEST MENU
CANCELLATION
"PROG/OK" to confirm
CLEAR ALL MEMORY
"PROG/OK" to confirm
CHANNEL FUNCTION
"PROG/OK" to confirm
"PROG/OK" to confirm
BACK TO RADIO CODES MENU
T B
F I
PROGRAM
Flashing on the display. You have to enter the programming mode to program the system.
F S
CP
T B
F I
OUT OF POS
During normal operation it indicates that the "automatic repositioning" procedure is about to take place. In
F S
CP
this case any commands received (TA, TC, TAL or TD) will automatically start this procedure.
This happens when an N.C. contact is activated (FI, FS, CP) during encoder programming or automatic
STOP PROG
T B
F I
repositioning. Once the passive state of the security devices has been reset the gate will start moving
AUTO PROG
F S
CP
again automatically. It also happens if a blackout occurs during programming.
Safety device test error. Check the condition of the safety devices and make sure that the alarm cuts in
T B
F I
when an obstacle interferes with the beam (the relative LED will switch off). In case of anomalies replace
SAFETY ERR
F S
CP
the damaged safety device or bridge the contact and deactivate the safety test (option menu).
This occurs when the programmer sends a command to the motor and nothing happens (the motor
T B
F I
doesn't move). Check the motor faston connections and the condition of the fuses "F2", "F3" and then
ERROR MOT1
F S
CP
give another opening or closing command. If the motor still doesn't move you are faced with either a
mechanical problem or a problem with the programmer.
T B
F I
If this error occurs during normal motor operation it means that there is a problem with one of the encoder
ERROR ENC1
F S
CP
signals. Check the relative connections and carry out automatic repositioning.
The gate movement direction is different from the encoder setting (eg. the gate moves in the closing
T B
F I
direction while the program is carrying out the opening stage). Check the motor power supply
ERROR DIR1
F S
CP
connections.
T B
F
I
Current sensor error. When the gate is not moving this symbol means there is a problem with the current
ERR. SENS1
F S
CP
sensor.
When the safety edge intervenes the gate will automatically invert for 5 cm, both in the closing as well as
T B
F
I
the opening direction, to free the obstacle it will then stop for 3 minutes and then continue moving in the
ACT. EDGE
F S
CP
original direction after a 10 second preflashing period has elapsed.
When the sensor intervenes the gate will automatically invert for 5 cm, both in the closing as well as the
T B
F
I
opening direction, to free the obstacle it will then stop for 3 minutes and then continue moving in the
ACT. SENS
F S
CP
original direction after a 10 second preflashing period has elapsed.
Language choice:
• Press the right and left buttons simultaneously to enter
the language submenu.
REMOTE
OK
• Press the right and left buttons to change the language:
Italian to French.
• Press the "PROG/OK" button to confirm the choice.
MEMORISE
OK
MEMORISE [nr ...]
Activation 1
OK
CANCEL [nr ...]
Activation 1
OK
CLEAR ALL MEMORY?
Exit
"PROG/OK" to confIrm
OK
CHANNEL A
COMMAND TD/TAL/TA/TC/
STOP/NO COMMAND
"PROG/OK" to set
EXIT
OK
Alarm indications
PRESS the
MEMORISE [nr ...]
transmitter
channel to be
Activation 2
memorised
PRESS the
CANCEL [nr ...]
transmitter
channel to be
Activation 2
cancelled
CANCELLING.....
OK
CHANNEL B
COMMAND TD/TAL/TA/TC/
STOP/ NO COMMAND
"PROG/OK" to set
CHANNEL D
COMMAND TD/TAL/TA/TC/
STOP/ NO COMMAND
"PROG/OK" to set
17
T B
F I
PROGRAM
F S
C P
Press the right and left buttons
simltaneously to enter the
language submenu
ENGLISH
OK
"PROG/OK" to confirm
PRESS the
MEMORISE [nr ...]
transmitter
channel to be
CODE MEMORISED
memorised
PRESS the
CANCEL [nr ...]
transmitter
channel to be
CODE CANCELLED
cancelled
CHANNEL C
COMMAND TD/TAL/TA/TC/
STOP/ NO COMMAND
"PROG/OK" to set
EXIT
OK
"PROG/OK" to set
BACK TO CHANNEL FUNCTION MENU
Operational indications
Pause time programming or
T B
F I
PAUSE
pause for automatic reclosing
F S
CP
(if activated)
T B
F I
Automatic programming under
AUTO PROG
way
F S
CP
T B
F I
OPENING
Opening stage
F S
CP
T B
F I
STOP OPEN
Block during opening
F S
CP
T B
F I
CLOSING
Closing stage
F S
CP
T B
F I
STOP CLOSE
Block during closing
F S
CP
T B
F I
UPDAT.SNS1
Current sensor updating (only
F S
CP
during programming)
TEST
T B
F
I
Test mode
F S
CP
T B
F
I
Battery mode with a fully
BATT. [99%]
F S
CP
charged battery
Battery mode with a
T B
F
I
discharged battery. The motor
BATT. [0%]
and commands will be
F S
CP
blocked.