cleanAIR AerGO CNA-042-R05 Mode D'emploi page 5

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 16
Ord. no.
Filter type
30 03 57
A1 P R SL
30 03 64
A1B1E1 P R SL
How to replace CleanAIR® AerGO® filters
Filters are removed from the unit by unscrewing them one by one separately in a counterclock-
wise direction.
New filters must be attached to the unit one by one, by screwing the filters into the unit's body
in a clockwise direction. Ensure they are properly tightened, which guarantees leak tightness.
Installing the prefilter/odour filter and the spark arrester
Remove the filter cover away from the filter body by pulling its protrusion. Place the prefilter/odour
filter and the spark arrester into the recess in the filter's body (place the prefilter/odour filter first and
only then place the spark arrester – if placed otherwise, the spark arrester cannot work properly!).
Secure the new prefilter and the spark arrester by snapping the filter cover.
Warnings!
The filters cannot be cleaned in anyway! Do not attempt to clean the filter using for example
compressed air as this will destroy the filter and will cause the loss of the expected protection and
the warranty will be invalidated!
The user must know the kind of air contamination in the ambinet air as well as its concentration.
The CleanAIR® AerGO® system must not be used in environments with a concentration of oxygen
lower than 17 %.
The CleanAIR® AerGO® system must not be used in environments immediately dangerous to life
or health (IDLH)!
The CleanAIR® AerGO® system must NOT be used in confined spaces, such as closed tanks, tun-
nels, canals, etc.
Filters designed to capture solid and liquid particles (particle filters) do not protect their users
against any gases.
If any of the instructions for use of the filter
Standards
EN 12941 / A2
X
EN 12941 / A2
X
X
is not
fulfilled, the warranty is invalid!
X
X
X
5