Cleaning programs
5090cc: The hygiene status will be analyzed and one
of the following program indicators will light up.
«
»
short economical cleaning required
«
»
normal level of cleaning required
«
» high intensive cleaning required
5070cc/5050cc: One standard cleaning program
included.
Start automatic cleaning
Start the cleaning process by pressing the start
button (16). If status light (15a) does not shine
(Clean&Charge Station switches to stand-by after
ca. 10 minutes), press start button twice. Otherwise
cleaning will not start.
For best shaving results, we recommend
cleaning after each shave.
Each cleaning program consists of several cycles,
where cleaning fluid is flushed through the shaver
head. Depending on your Clean&Charge Station
model and/or program selected, the cleaning time
takes up to 3 minutes. During this time the status light
blinks. Leave the shaver in the station for drying.
It takes several hours until remaining moisture
evaporates depending on the climatic conditions.
Afterwards the shaver is ready for use.
After completing the cleaning and charging proce-
dure, all indicators turn off.
Removing the shaver from the Clean&Charge
Station (see fig. E)
Hold the Clean&Charge Station with one hand and
tilt the shaver slightly to the front to release it.
Cleaning Cartridge / Replacement (see fig. F)
When the level indicator
red, the remaining fluid in the cartridge is sufficient
for about 3 more cycles*. When the level indicator
blinks red, the cartridge needs to be replaced -
about every 4 weeks* (*when used daily).
After having pressed the lift button (13) to open the
housing, wait for a few seconds before removing
the used cartridge to avoid any dripping. Before
discarding the used cartridge, make sure to close
the openings using the lid of the new cartridge,
8
lights up permanently
since the used cartridge will contain contaminated
cleaning solution.
The hygienic cleaning cartridge contains ethanol
(note: cartridges sold in RU/BY/UA contain
izopropanol), which once opened will naturally
evaporate slowly into the surrounding air. Each
cartridge, if not used daily, should be replaced after
approximately 8 weeks to ensure optimal disinfection.
The cleaning cartridge also contains lubricants for
the shaving system, which may leave residual marks
on the outer foil frame and the cleaning chamber
of the Clean&Charge Station. These marks can be
removed easily by wiping gently with a damp cloth.
Do not refill the cartridge and use only original
Braun refill cartridges.

Accessories

Braun recommends changing your shaver's
Foil & Cutter cassette every 18 months to maintain
your shaver's maximum performance.
Available at your dealer or Braun Service Centres:
• Foil & Cutter cassette: 52S/52B
• Cleaning cartridge Clean&Charge Station: CCR
• Braun Shaver cleaner spray

Environmental notice

This product contains rechargeable batteries.
In the interest of protecting the environment,
please do not dispose of the product in the
household waste at the end of its useful life.
Disposal can take place at a Braun Service Centre
or at appropriate collection points provided in your
country.
The cleaning cartridge can be disposed of with
regular household waste.
Subject to change without notice.
For electric specifications, see printing on the
special cord set.