7.12- Clearing the OREV transmitter parameters

This procedure returns the OREV transmitter to its « factory »
confi guration (default confi guration on delivery), with the following
settings :
• Identity code group N°1,
• Radio transmit power level 4,
• «Normal» operating mode,
• Radio channel N°17,
• «Standby» time delay period of 4min.
 The procedure for clearing the parameters of the OREV
transmitter is performed using internal button S1 of the
transmitter.
S1
+
1
Open the housing of the OREV transmitter.
Press and hold button S1 for around 10 seconds.
The Va
2
Clearing and re-programming of the « factory » parameters of the transmitter is
completed when the Va
3
Close the housing of the OREV transmitter.
FR
- 100 -
ON
1
2
3
4
5
6
7
8
+
and Vb
indicator lights of the transmitter fl ash alternately.
EN
DE
Va
and Vb
indicator lights go off.