8.7- Product wiring
8.7.1- Wiring recommendations
Use control components with integrated noise suppression system.
Do not place cables of different classes side by side.
A minimum space (20 cm) should be observed between the different
classes:
Classe 1 : Radio, antenna cable (case of an antenna extension),
Classe 2 : Mains for power supply of various units,
Classe 3 : Power control for motors, variable speed drive, etc....
Ideally, each cable class should be run through a cable path specifi c to
the class. If only one cable path is available, cables of different classes
should be separated as much as possible.
8.7.2- Wiring the receiver ORR
If fl exible stranded wire is used, crimped terminations should be used
to avoid false contacts and short circuits.
DO NOT FORCE-INSERT THE WIRE IN THE TERMINAL ; THE
TERMINAL STRIP IS NOT AN « AUTOMATIC CONNECTION»
TERMINAL STRIP.
To open the ORRS and ORRA connection terminal strips :
1. Vertically insert the screwdriver (fl at
tip screwdriver of 1.5 to 3 mm width)
in the slot located opposite the wire,
2. Insert the wire,
3. Remove the screwdriver.
Orion - 324501G
To avoid any risks of electrocution, do not
open the receiver housing when receiver is
power supplied.
1
DE
EN
2
FR
- 105 -