It is mandatory that the Microsoft Bluetooth
driver is used to send the measured values via
Bluetooth from the TPA 200 to the PC/laptop. If
KTS modules and ESI[tronic] 2.0 are used, the
Toshiba Bluetooth driver cannot be used.
1. Start the "TPA Startcenter" software on the
PC/laptop.
i
The "TPA Startcenter" software must be ac-
tivated on the PC/laptop in order to pair and
activate the Bluetooth link.
2. Switch on the TPA 200.
Main Menu
is displayed.
Check
is displayed.
3. Select "Settings" with
with
.
General
is displayed.
4. Select "BT Pair" with
with
.
Searching...
is displayed.
 The number of Bluetooth devices found is
displayed.
i
On the TPA 200 a maximum of eight Blue-
tooth devices are displayed after the search.
If the PC/laptop, on which the "TPA Start-
center" is installed, is not displayed, the
reason for this may be, that more than eight
Bluetooth devices have been found. In this
case the Bluetooth devices, which are not
being used, must be shut down.
5. Confirm with
.
6. Select the desired Bluetooth link with
and confirm with
 The Bluetooth link is paired, activated and
connected.
7. Select "<Back" with
with
to get into the main menu.
"
The Bluetooth link is set up.
5.8.3
Info
The software version with the version date and
serial number of the TPA 200 is displayed.
5.8.4
Update
The software of the TPA 200 can be updated.
The vehicle database is also updated. The soft-
ware update is always started beginning with
the "TPA Startcenter" software.
Robert Bosch GmbH
or
and confirm
or
and confirm
or
.
or
and confirm
Operation | TPA 200 | 29
For further information see "TPA Startcenter"
online help.
i
Downloadable software updates are
regularly available on the website
http://bit.ly/bosch-tpa-startcenter.
Further information can be obtained from
your Customer Service agent.
5.9
Information in the case of any
faults with Bluetooth
Fault
The PC/laptop is not rec-
ognized as a Bluetooth de-
vice by the TPA 200.
Win 7 and Win 8:
If KTS modules and
ESI[tronic] 2.0 are used,
the PC/laptop is not rec-
ognized as a Bluetooth link
by the TPA 200.
Bluetooth range problems
between the TPA 200 and
PC/laptop.
5.10
Information in the case of
any faults
Fault
TPA 200 after turning on
without a display.
"Charge" symbol does not
appear on the display.
The sensor cannot be read,
because for example the
battery voltage of the sen-
sor is too low, or because
only three of the four sen-
sors are detected.
The sensor cannot be pro-
grammed.
1 689 989 200
en
Remedial measure
Check the Bluetooth set-
tings on the PC/laptop:
In the Options tab in the
Search input box the op-
tion for Bluetooth devices
can determine this PC/
laptop must be activated,
and in the Links input box
the option for Bluetooth
devices can establish a
link with this PC/laptop
must also be activated.
If KTS modules and
ESI[tronic] 2.0 are used,
the "DDC" software is in-
stalled on the PC/laptop.
The Microsoft Bluetooth
driver must be selected in
the "DDC".
We recommend use of
the Class 1 Bosch Blue-
tooth USB adapter
(1 687 023 777).
Remedial measure
Supply the TPA 200 with
power via the USB con-
necting cable.
If the "Charge" symbol ap-
pears on the display, ful-
ly charge the battery.
Then turn on the TPA 200
without a USB connect-
ing cable.
Check the USB connect-
ing cable or other USB
interface with the com-
puter, or use a different
computer.
Repeat the search or pro-
gramming and check
whether the sensor is
faulty.
|