During first 600 hours of work it is a good thing to check all nuts, since stress could sort out the structure. Control
the values that are reported in table.
After that repeat the control every 200 hours of work
13
17
19
22
24
27
30
32
36
Figure 8-3. Screws tightening torque (Nm)
Copyright ©2009 della Alpego spa® - All rights are reserved. Reprinting or unauthorized use of this manual is strictly forbidden without written permission by Alpego spa
1.25
M 8
1.00
1.50
M 10
1.25
1.75
M 12
1.25
2.00
M 14
1.50
2.00
M 16
1.50
2.50
M 18
1.50
2.50
M 20
1.50
2.50
M 22
1.50
3.00
M 24
2.00
8.8
10.9
[ Nm ]
[ Nm ]
25
37
27
40
50
73
53
78
86
127
95
139
137
201
150
220
214
314
229
336
306
435
345
491
432
615
482
687
502
843
654
932
744
1080
814
1160
Old Cod.Q00A00142
New Cod. MANT2010/00493 R.1
12.9
[ Nm ]
44
47
86
91
148
163
235
257
369
393
509
575
719
804
987
1090
1240
1360