Eaton SEB 9 Mode D'emploi page 11

Projecteur portatif pour atmosphère explosive
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7.
Operation and fault analysis
Operation
Switch position
Main beam on
Pilot lamp
dimmed
Pilot lamp
Main lamp
Main lamp
Main lamp
Flashing
flashing
mean beam
Flashing
mean beam
Charging
OFF
OFF
Main lamp
Flashing
main lamp
Pilot lamp
Subject to alteration or supplement of the product series.
Explosion protected portable searchlight
SEB 9, SEB 9 L
Flashg.
Pilot light
main beam
on
EATON's Crouse-Hinds Business
LED display
Cause
pulsing red
Defect. pilot lp.
none
Function ok
Acc. to batt.
Defect. main lamp
capacity
Acc. to batt.
Function ok
capacity
only red LED
Deep discharge
or none
protection active
function ok
Acc. to batt.
Function ok
capacity
Acc. to batt.
Defect. main lamp
capacity
Acc. to batt.
Charging
cap. or leading
completed
LED pulsing
None
Defective
electronics
Acc. to batt.
Function ok
cap. or leading
LED pulsing
Acc. to batt.
Function ok
cap. or leading
LED pulsing
Acc. to batt.
Recharge
cap. or leading
period extended
LED pulsing
to 28 hours
E
Measure
Replace pilot lamp
None
Replace main lamp
None
Recharge
None
Replace main lamp
None
Searchlight
to be passed
for repair
None
None
None or switch
to OFF pos.
11

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Seb 9 l

Table des Matières