Installation Instructions
*NOTE: The blocked letters, such as A, shown below, refer to illus-
trations on Pages 2 & 4. Match these to the related text pages.
Overall Dimensions A.................................................................... 2
Power Supply B ............................................................................ 2
Cabinet Preparation and Clearances C ........................................ 2, 3
Junction Box Location D ................................................................ 2
Countertop Cutout Dimensions E ................................................... 2
Installing the Cooktop F ................................................................ 4
Secure Cooktop to Countertop G ................................................... 4
Solid Surface Countertop Installs H ................................................ 4
Installation above a Single Oven I, J, K, and L .............................. 4
Electrical Connection ..................................................................... 5
IMPORTANT:
INSTALLER:
OWNER:
READ AND SAVE THESE INSTRUCTIONS
OVERALL DIMENSIONS
See Illustration A, Page 2. These dimensions are
overall.
POWER SUPPLY
ELECTRICAL POWER CONNECTION FOR
COOKTOP
Power Supply is dual rated: 240 Volts or 208 Volts, 4
wire, 60 Hz, with the following circuit breaker
requirements: Models CEF304, CET304 or CEP304 at
30 Amps; Models CEF365, CET365 or CEP365 at 40
Amps or Model CEP456 at 50 Amps
Install a junction box (not supplied), below the counter
top within 3 feet of flexible conduit (supplied) located
at the right rear corner of the cooktop rough-in box.
TABLE OF CONTENTS *
Save these instructions for Local Electrical Inspector's use.
Please leave these Installation Instructions with this unit for the owner.
Please retain these instructions for future reference.
A
B
Models: CEF304, CEF365, CET304, CET365, CEP304, CEP365, CEP456
JUNCTION BOX LOCATION
Plan the installation of the unit so that the location of
the junction box is within 3 feet of the right rear of the
cooktop bottom. It must be accessible from the
front of the cabinet. (An exception to this location
would be for a cooktop installation over a single electric
oven In that situation, refer to Pages 4 and 5 and
Figures I, J, K and L.