CONNECTING THE FEEDER CABLE
mod. 106 EX 939
To connect the feeder cable to the cook-
er it is necessary to:
– Remove the two screws that hold
s h i e l d " A " b e h i n d t h e c o o k e r
(fig. 11.4).
– Open completely the cable clamp
"D".
– Fitted with a 5-pole terminal block,
position the U bolts onto terminal
block "B" (fig. 11.4) according to the
diagrams in figs. 11.5 - 11.6.
– Feed the supply cable through the cable
clamp "D". The supply cable must be
of a suitable size for the current require-
ments of the appliance; see the section
"Feeder cable section"
– Connect the phase and earth cables
to terminal "B" according figure
11.5 and 11.6.
– Pull the feeder cable and block it with
the cable clamp "D".
– Re-mount shield "A".
N.B. Earth cable must be 3 cm longer
than neutral and live cables.
D
Fig. 11.4
72
FEEDER CABLE SECTION
"TYPE H05RR-F"
230 V - 240 V
230 V3 - 240 V3
400 V 3N - 415 V 3N
400 V 2N - 415 V 2N
(**) – Connection with wall box connection.
– Contemporaneity factor applied
B
A
3 x 6 mm
2
4 x 4 mm
2
5 x 2,5 mm
4 x 4 mm
2
230 V - 240 V
1 2 3 4 5
L
N (L
)
PE
1
2
230 V3 - 240 V3
1 2 3 4 5
L
L
L
PE
1
2
3
400 V 3N - 415 V 3N
1 2 3 4 5
L
L
L
N
PE
1
2
3
400 V 2N - 415 V 2N
1 2 3 4 5
L
L
N
PE
1
2
Fig. 11.5
(**)
(**)
(**)
2
(**)