Télécharger Imprimer la page

Proosten Electronics Proline LBC 400 Série Manuel D'utilisation page 16

Publicité

Les langues disponibles
  • FR

Les langues disponibles

No battery is
connected but the
green LED from
'charge process'
burns when the
charger is activated.
The battery isn't
charged fully, but the
charged indicates the
charging process is
finished.
When the LBC 400 still is not functioning well after the actions stipulated,
you may return the charger to your retailer. The charger must be sent
prepaid.
A B O U T T H E B A T T E R Y
Follow the instructions of the manufacturer when using and handling the
battery.
CAUTION!
A battery contains corrosive sulphuric acid. Any contact with this acid can
cause permanent damage to eyes, skin, clothes etc. If you have had
accidental contact with this acid, then you should wash it off immediately
with plenty of water. When the acid has come into contact with your eyes,
you should consult a doctor without delay.
Important
Check the degree of acidity of the battery on a regular basis
- once every two weeks.
- full-traction and semi-traction; once every week
-batteries which are put away for the winter; once every month.
The level of the acid (electrolyte) should be +/- 1 cm above the plates.
Use only distilled or denaturized water when topping up the battery.
Never use battery acid!
The charger always
gives a output
voltage, irrespective
of the present of a
battery.
The battery is
defective.
There are heavy
consumers connected
to the battery.
battery is too heavy
for the charger.
English
Switch the charger
off. Always firstly
connect a battery.
Measure the acid
and, if necessary,
replace the battery.
Connect a heavier
charger to the
battery.
16

Publicité

loading

Ce manuel est également adapté pour:

Proline lbc 412Proline lbc 424